Scope of V/ork

ATC Associates, Inc. (ATC) was retained by New York City Board of Education (NYC- BOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were collected from areas specified in H.A. BADER Consultants, Inc. letter to Stuyvesant HS parents dated October 10, 2001 and were requested by the United Federation of Teachers (UFT) industrial hygienist Ms. Ellie Engler. These areas are the following:

• r'and 2"'’floors entrance lobby • Classrooms with unit ventilators on the North, East and South side of the building • Two hallway areas • r' floor swimming pool area • 3“' floor gymnasium area • 5“’ floor cafeteria area • Auditorium area

The purposed of the dust wipe sampling is to determine if dust in the school contains lead. This additional dust wipe sampling was requested by UFT and it was approved by NYC-BOE.

ATC’s representative Mr. Jimmy Choy visited Stuyvesant HS (M477) located at 345 Chamber Street, New York, NY on February 23’’'’, 2002. Dust wipes to be analyzed for lead content were collected from the aforementioned areas indicated in H.A. BADER Consultants, Inc. letter to Stuyvesant HS parents and as specified by the New York City Board of Education Environmental Health & Safety Unit and in accordance with HUD protocols.

LEAD-IN-DUST SAMPLING

Lead-in-dust threshold levels The New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred (coimnonly referred to as “final clearance” levels). As stated in the Code, final clearance after abatement ha,s taken place is achieved when dust wipe samples indicate lead levels below those listed below:

For Windowsills: 250 pg/fF For Floors: 40 pg/ft"

Although the lead-in-dust samples collected at Stuyvesant HS (M477) were not collected in response to lead abatement, the same thresholds are used since no other regulations or standards are applicable to this project.

Sluyvesant HS (M477J Owe »6S0CIA I 6t INC February 25. 2002

CITY_21MC100_003072819

NYC-WTC_000336742

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000336742Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →