NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM asbestos dust count sheet

Machine-extracted title · confidence 100%

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

NYC-WTC_000335588
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TEM Asbestos (MICROVAC) Count Sheet Client Name: NYC BOE Volume (ML): 20 Lab Group E: 04 s I Surface Area Sampled 100 I.ab Sample #: <)

C ient Sample #: 00-00 Magnification: 20.000

GRID BOX: Accelerating Voltage: 100 KeV GRID ID: # Grid Openings: 5 AnalvsisDate: 1/28/02

Analysis Performed By; MARK PEYSAKHOV

GO, Structure Stru::ure Type Length ID of Structure EDS (Nonadb No F 3 C M Chrys Amphibole I Ncnasb j Amoig/ND i t Elsrnenls)

—

E-f' U- -4

! I ------

H Stri Ct = > 5.Op > 3:1 Aspect Ratio Grid acceptance:

n/= Positive diffraction pattern o'operties conforming to <50% undissolved filter, overlapped or folded Totals labOi'atory identification criteria observec <10% particulate coverage >50% coverage ate

EDS spectrum conforming to laboratory least 20 unfolded or overlapped grid squares <5% holes or opaque areas Fp i \i ".

identification c-itena cbsen/ed Chrysotile ! i i

F = S'lingle Fiber B = fiundle (<3 fibers <1 fiber diameter apart .amphiboles Amosite Crocidolite Amphibole Ambiguous "t" ~i i C = Cluster (>3 intersections) Aothophyllile Non-Asbestos Tremolite M = Matrix Actinolite Non-Identified NSD = Nc Structures Detected

CITY_21MC100_003059108

NYC-WTC_000335588

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000335588Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

TEM asbestos dust count sheet · Box unavailable

NYC-WTC_000335589

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

7 shared non-person entities · 1 shared topics · similarity 0.990

machine-extracted · confidence unavailable · Check page ↗
TEM asbestos dust count sheet · Box unavailable

NYC-WTC_000335583

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

7 shared non-person entities · 1 shared topics · similarity 0.990

machine-extracted · confidence unavailable · Check page ↗
TEM asbestos dust count sheet · Box unavailable

NYC-WTC_000189768

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

7 shared non-person entities · 1 shared topics · similarity 0.988

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

TEM asbestos dust count sheet · page 1

NYC-WTC_000335589

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

Similarity score 0.995 (not a probability)

machine-extracted · confidence unavailable · Check page ↗
TEM asbestos dust count sheet · page 1

NYC-WTC_000335583

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

Similarity score 0.995 (not a probability)

machine-extracted · confidence unavailable · Check page ↗
TEM asbestos dust count sheet · page 1

NYC-WTC_000189768

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

Similarity score 0.994 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

TEM asbestos dust count sheet

NYC-WTC_000335589

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

Similar indexed content

TEM asbestos dust count sheet

NYC-WTC_000335583

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

Similar indexed content

TEM asbestos dust count sheet

NYC-WTC_000189768

Laboratory bench sheet tallying asbestos structures seen by electron microscope for a settled-dust (microvacuum) sample; raw counts, not the reported result.

Similar indexed content

Compare copies and versions →