NYC 9/11 Public Portal Document
104 East 25th St., 10th Floor
New York, New York 10010
WWW atc-enviro.com
212.353.8280
Fax 212 353.8306
t- ASSOCIATES INC.
December 3, 2001
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Hydrocarbons, Mercury, Metals and Silica
P. S. 234M
ATC Project No. 15-19125-0279
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for
hydrocarbons, mercury, metals and silica conducted on November 13, 2002, at the
referenced school. The New York City Department of Education (DOE) requested this
sampling to verify that acceptable air quality is being maintained in the school building.
ATC collected four (4) samples each for hydrocarbon compounds (HC), mercury, metals
and seven (7) samples for silica at specified locations. All samples were collected for
ten (10) hours.
SAMPLING METHODOLOGY
For the HC, ATC used activated coconut shell charcoal tubes connected to battery-
powered sampling pumps at a flow rate of 0.2 liters per minute (L/M). Metal samples
were collected using mixed cellulose ester filters and pumps set to draw 2.0 L/M.
Mercury vapor samples were collected using Carulite® (Hydrar) tubes connected to
battery-powered sampling pumps calibrated to collect 0.2 L/M. Respirable dust (silica)
samples were collected using pre-weighed 37mm PVC filters connected to size-selective
cyclones to remove the larger (non-respirable) particles prior to deposition on the filters.
All of the silica samples were collected indoors. All sampling pumps were calibrated
before and after each sampling period. Three (3) samples for HC, mercury and metals
were collected inside the building and one (1) was collected outdoors. One blank tube
each for HC and mercury were also submitted. Two blank MCE filters for metals were
submitted and one blank pre-weighted PVC filter was submitted.
METHOD OF ANALYSIS
All samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene
Association-accredited laboratory in Reading, PA.
CITY_21MC100_0 03058548
NYC-WTC_000335198
OCR can misread numbers and units. Confirm readings against the page image before using them.