NYC 9/11 Public Portal Document
Pace Analytical Services, Inc
1700 Elm Street-Suite 200
Minneapolis, MN 55414
'^ace Analytical__________ Method 8290 Analysis Results
Tel. 612-607-1700
Fax 612-607-6444
Client - ATC ASSOCIATES
Client's Sample ID ATC-1114-89M-DX3
Lab Sample ID 104041561
Filename F21204B_14
Injected By MRO
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution 2
Dry Weight Extracted NA Collected 11/14/2002
ICAL Date 11/25/2002 Received 11/15/2002
CCal Filename(s) F21204B_01 &F21204B_16 Extracted 11/25/2002
Method Blank ID BLANK-2453 Analyzed 12/05/2002 05:18
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0084 0.0040 J 2,3.7,8-TCDF-13C 2.00 95
Total TCDF 0.0770 0.0040 2,3,7,8-TCDD-13C 2.00 97
1,2,3,7,8-PeCDF-13C 2.00 75
2,3,7,8-TGDD ND 0.0040 2,3,4,7,8-PeCDF-13C 2.00 66
Total TCDD 0.0110 0.0040 J 1,2,3.7.8-PeCDD-13C 2.00 68
1.2.3.4.7.8-HxCDF-13C 2.00 133
1,2,3.7,8-PeCDF ND 0.0200 1,2,3.6,7.8-HxCDF-13C 2.00 99
2,3,4,7,8-PeCDF ND 0.0200 2,3,4,6.7,8-HxCDF-13C 2.00 104
Total PeCDF ND 0.0200 1,2,3,7.8,9-HxCDF-13C 2.00 101
1,2,3,4,7,8-HxCDD-13C 2.00 118
1.2.3,7,8-PeCDD ND 0.0200 1,2.3,6,7,8-HxCDD-13C 2.00 92
Total PeCDD ND 0.0200 1,2,3,4,6,7,8-HpCDF-13C 2.00 86
1,2.3,4,7.8.9-HpCDF-13C 2.00 72
1.2.3.4,7,8-HxCDF ND 0.0200 1,2.3,4,6,7.8-HpCDD-13C 2.00 70
1,2,3,6,7.8-HxCDF ND 0.0200 OCDD-13C 4.00 75
2,3,4.6,7,8-HxCDF ND 0.0200
1,2,3,7.8,9-HxCDF ND 0.0200 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0200 1,2.3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7.8-HxCDD ND 0.0200 2,3,7,8-TCDD-37CI4 0.20 99
1,2.3,6,7,8-HxCDD ND 0.0200
1.2,3,7,8,9-HxCDD ND 0.0200
Total HxCDD ND 0.0200
1.2,3,4,6.7.8-HpCDF ND 0.0200 Total 2,3,7.8-TCDD
1,2,3,4,7.8,9-HpCDF ND 0.0200 Equivalence: 0.0010 ng/m2
Total HpCDF ND 0.0200 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.0200
Total HpCDD ND 0.0200
OCDF 0.0850 0.0400 J
OCDD 0.1200 0.0400
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ‘ = See Discussion
Report No.... 1065493
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc
CITY_21MC100_003058079
NYC-WTC_000334906
OCR can misread numbers and units. Confirm readings against the page image before using them.