NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air sampling for mercury, P.S. 150M, Mar 2002

Machine-extracted title · confidence 42%

ATC letter report of mercury vapor air sampling at P.S. 150M on Mar 4, 2002.

NYC-WTC_000334732–000334733
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St New York, New York 10013 v/ww.atc-enviro.com 212 353 8.230 Fax 212,353.8306 ASSOCIATES INC.

March 18, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York C ity Board of Education 28-1 ! Queens Plaza North Long Island City, NY 11101

Re: .Air Sampling for Mercury P.S. 150M ATC Project No. 1.5-19125-0289

Dt;ar Mr. Ori an:

ATC Associates, Ine. (ATC) is pleased to provide this letter report of air sampling for mercury vapor conducted on March 4, 2002, al the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of Environ Corp., a consultant to the parent’s association.

ATC collected three (3) samples for mercuty' vapor using Carulite’^ (Hydrar) tubes connected to battery-powered sampling pumps calibrated to collect 0.2 liters of air per minute. Samples were collected for ten (10) hours. Two (2) samples were collected outdoors and one (1) was collected indoors. The samples were sent to PSC Analytical Services, Ine., an American Industrial Hygiene Association-accredited laboratory’ in Reading, PA. One blank tube was also submitted. Analysis was performed by means of a mercury' analyzer according to NIOSH Method 6009. A copy of the analytical laboratory report is attached.

The sampling locations were: the 1" floor lobby, Outdoor-Plaza, and the Roof.

The blank-corrected mercuiy' concentrations are shown in the table.

i LOCATION MICROGRAMS MICROGSAMS/M" MICROGRAMS/M^ PER SAMPLE DETECTED CORRECTED

Plaza - Outdoors 0.0250 0.208 BDL*

Lobby 0.0250 0.208 BDL

Roof 0.0260 0.217 0.0166

Blank 0.0240 J* ___ 3____ I Below Detection Limn

CITY_21MC100_003068012

NYC-WTC_000334732

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000334732Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.