Air monitoring data, Lower Manhattan, Oct 2001

Machine-extracted title · confidence 41%

Lower Manhattan air monitoring entries for 10/4/01.

NYC-WTC_000334587
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I Lower Manhattan Testing Lower Manhattan Testing Collection Date; 10/4/01 Collection Date: 10/4/01

I Location Sampled Park PI & Church^ Murray St & Church St Air Monitoring Table Ambient/lndoor Fiber Cone PCM (f/cd Asbestos Cone. TEH (nrutymma Ambient Ambient <100 0.014 <6.56 Rs Park PI & Greenwich St Ambient Q.03Q 6.56 Murray St & Greenwich St Ambient 0.019 <6.56’ Fulton St & Church St Ambient ____ 0.016______ <6.56 Trinity PIS Thames St Ambient 0,077 6.56 Warren Sts North End Av Ambient 0,014 <6.56 RiverTerraceSPark PI West Ambient <100 RiverTerrace & Chambers St Ambient <100 River Terrace.Park Area Ambient <Loa West Sts Warren St Ambient <LOQ North End Av S Park Pl West Ambient <LOQ RiverTerraceSVeseySt Ambient <LOQ

s § South End AvS AlbanySt Rector PI, by the Park West Thames St/WaterfroH WestofThirdPI__ Ambient Ambient Ambient Ambient 0.012 <LOQ <100 0.011 ’ 0.012 6.56

<6.56 ___ West Sts Albany Ambient <6,56 Gateway Plaza,Park Area Ambient "0,022' <6.56

Daily Field Survey Instrument Levels Found FoxboroTVAlMQ Rome-lonizotion/Photo- t D?te<roi DetecTion of miofile photo iofiucble and hammable compoundi ND 6astecliGT402 Combustible Gas Indicate Oetectionof: H^dcndgai Sulfide NO O^en 20.9% CarhzinUanoidde 2-8 P.M. 1 Crown Tripl-: Plus lower Explosive limit ND

Specialized Detectors Detection of: Hvdiodaen Cyamide ND 2 Chlorine NO Ammonia NO CQibon Mynojiide 2-8 P.W. RKI Freon Detector Specialized InstTumet)! for Dnedionotrieom Detection of: R22 ND

60 61 B

NYC-WTC_000334587

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000334587Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Lower Manhattan air monitoring data, Oct 10, 2001

NYC-WTC_000203404

Air monitoring table recording ambient fiber concentrations and volatile organic compound detection levels at various Lower Manhattan locations on October 10, 2001.

Similar indexed content

Compare copies and versions →