NYC-WTC_000334556
Air monitoring data for 9/18/01; ambient and indoor PCM/TEM measurements.
3 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗Air monitoring data for 9/15/01 at Lower Manhattan sites; indoor/ambient measurements.
NYC-WTC_000334554OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Lower Manhattan Testing Lower Manhattan Testing Collection Date: 9/15/01 Collection Date: 9/15/01
Air Monitoring Table Location Sampled AmbienVIndoor Fiber Cone PCM (»«) Asbestos Cone TEM (smicymma Murray St & Church St Ambient 0.022 120.13 Murray St Ambient 0.024 Overload between Chordi & Broadway
Fulton St Ambient 0.035 131.23 Jerwwn Ch jrdi & Broadway
Fulton St & Church St Ambient 0.034 Overload gc; Murray St & Greenwich St Ambient 0.031 Overload Broadway & Murray St Ambient 0.045 Overload Broadways Liberty St Ambient 0.00S2 Overload
■* Vesey St Ambient 0.035 Overload Between Qweh & Greenwich
Greenwich St & Park Pl Ambient 0.076 Overload Broadway & Cedar St Ambient 0.033 Overload
Daily Field Survey ^tovsr Instrument Levels Found FoxboroTVAIOOO ffome-fonizationyPhotQ-fonaatofl Detector Deteition ofvolertilephoto iorveoble and flammable compounds ND Gastech GT 402 rvnhiKtibfe 6as Indiartor Detection of: Hfdraig&TSulitde ND Oxygen 20.9% Qt.iionMonaxirfe 2-8 PM. l(werE^losfvc Limit NO Crown Triple Plus SpedatizEd DdKtm Detectian nf: Hydmfgei/Cyamiiie ND k; I Chlorine ND Ammonip ND I RKI Freon Detector Co.’bon Monoxide 2-8 PM.
’ip/'cialized Instrument for Defeclion of freons Detection of: 1122 ND
to 10 n co
NYC-WTC_000334554
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000334556
Air monitoring data for 9/18/01; ambient and indoor PCM/TEM measurements.
3 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334551
Ambient and indoor air monitoring data; various locations in Lower Manhattan.
3 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333181
Air monitoring data page for 9/13/01, listing PCM/TEM parameters and ambient readings.
3 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334577
Lower Manhattan air monitoring entries with ambient samples dated 9/29–9/30/01.
3 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333180
Air monitoring table for Lower Manhattan with PCM/TEM readings dated 9/12/01.
3 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334589
Lower Manhattan air monitoring table with ambient samples on 10/8/01.
3 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334555
Air monitoring data for 9/17/01 at Lower Manhattan sites; ambient measurements.
2 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334568
Air monitoring data for 9/24/01; ambient readings at multiple sites.
3 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334560
Air monitoring data for 9/21/01; ambient readings for PCM/TEM measurements.
3 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334552
Air monitoring data for 9/13/01 at multiple sites in Lower Manhattan.
3 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000203393
Table recording ambient air fiber counts and temperature data from Lower Manhattan locations.
2 shared non-person entities · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334570
Air monitoring data for 9/25/01; ambient readings and <LOQ values.
3 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000334556
Air monitoring data for 9/18/01; ambient and indoor PCM/TEM measurements.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334551
Ambient and indoor air monitoring data; various locations in Lower Manhattan.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334577
Lower Manhattan air monitoring entries with ambient samples dated 9/29–9/30/01.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000334556
Air monitoring data for 9/18/01; ambient and indoor PCM/TEM measurements.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333181
Air monitoring data page for 9/13/01, listing PCM/TEM parameters and ambient readings.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333180
Air monitoring table for Lower Manhattan with PCM/TEM readings dated 9/12/01.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000334556
Air monitoring data for 9/18/01; ambient and indoor PCM/TEM measurements.
Similar indexed content
NYC-WTC_000334551
Ambient and indoor air monitoring data; various locations in Lower Manhattan.
Similar indexed content
NYC-WTC_000333181
Air monitoring data page for 9/13/01, listing PCM/TEM parameters and ambient readings.
Similar indexed content
NYC-WTC_000334577
Lower Manhattan air monitoring entries with ambient samples dated 9/29–9/30/01.
Similar indexed content
NYC-WTC_000333180
Air monitoring table for Lower Manhattan with PCM/TEM readings dated 9/12/01.
Similar indexed content