NYC 9/11 Public Portal Document
Lower Manhattan Testing
Collection Date: 10/3/01
Air Monitoring Table
Location Sampled Ambient/lndoor Fiber Cone. PCM (f/a) Asbestos Cone. TEM (struc./mni2)
Park P!& Church St Ambient <LOQ
Murray St & Church St Ambient <LOQ
Park PI & Greenwich St Ambient <LOQ
Murray St & Greenwich St Ambient 0.021 <6.56
Fulton St & Church St Ambient 0.023 <656
Trinity Pl & Thames St Ambient 0.020 6.56
Warren St & North End Av Ambient 0.010 <6.56
RiverTerrace&Park PI West Ambient <L0Q
RiverTerrace & Chambers St Ambient <L0Q
RiverTerrace, Park Area Ambient <L0Q
West St & Warren St Ambient <L0Q
North End Av & Park PI West Ambient <LOQ
River Terrace & Vesey St Ambient <LOQ
South End Av & Albany St Ambient <LOQ
Rector PI, by the Park Ambient <LOQ
West Thames St, Waterfront Ambient 0.011 <6,56
West of Third Pl Ambient <L0Q
West St & Albany Ambient <LOQ
Gateway Plaza, Park Area Ambient 0.010 <6.56
Daily Field Survey
Instrument Levels Found
FoxboroTVAWOO
Flame-lonization/Photo-lonizaton Detector
Detection of volatile photo ionizable and flammable compounds ND
Gastech GT 402
Combustible Gas Indicator Detection of: hydrodgen Sulfide ND
Oxygen 20.9%
CarbonMonoxide 2-8 RM.
Lower Explosive Limit ND
Crown Triple Plus
Specialized Detectors Detection of: Hydrodgen Cyamide ND
Chlorine ND
Ammonia ND
Carbon Monoxide 2-8 RM.
RKl Freon Detector
Specialized Instrument for Detection of Freons Detection of: P,-22 ND
B44
CITY_21MC100_002468203
NYC-WTC_000333164