NYC-WTC_000333063
HVAC inspection details and qualifications for WTC-related building.
11 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗Post-9/11 HVAC inspection details for 375 [name] Ave, Dec 2002.
NYC-WTC_000333061–000333062OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
375 South End Avenue, Manhattan, NY December 09,2002
Inspection Details;
As part of the survey, the following HVAC system types were inspected by Mechanical and Environmental professionals and bulk sample was collected from exhaust duct in the basement-mechanical phone room. All identification data and visual inspections are documented in the attached checklists.
A. Kitchen and batliroom exhaust - located on the roof and basement B. HVAC (7)Units-located on the lobby. C. Compactor room exhaust&intake,CVD24 exhaust, gym exhaust(no filter installed)-located on the basement. D. Heeding for the East side of the hallways - located on the roof. E. Heating for the West side hallways - located on the roof. F. AJC# 1 for the elevator room - located on the upper bulkhead. G. A/C #2 for the elevator room - located on the bulkhead.
Summary cl Findings:
During our visual inspection of the various HVAC systems black dust (less than 1/16"' of an inch) was observed in the following exhaust fans. Exhaust fan)/8,t/16 located on the roof. Exhaust fan #01 -CVD24-iocated on the basement. This was recorded in the Ventilation system evaluation forms. Bulk sample was collected and WTC related dust was NOT detected by EMSL Analytical, Inc
Scope of work: WTC related dust must be removed from the following:
Exhaust fans #8,16 located on the roof along with their associated components and their ducts Compactor room exhaust #01& intake,CVD24 exhaust, gym exhaust(no filter installed)- located on the basement along with their associated components and their ducts.
Should you require any further information, please feel free to contact me.
Sincerely,
life’ Vasilis Bellos Director of Operations
Attachments: 1) Ventilation System Evaluation forms 2) EMSL Lab results & Chain of Custodies
CITY_21MC100_011103006
NYC-WTC_000333062
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000333063
HVAC inspection details and qualifications for WTC-related building.
11 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333059
Agency coordination on HVAC inspections conducted Oct 31, 2002 and Mar 4, 2003.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333057
memo documenting HVAC and environmental inspections for a building at 375 Avenue, NYC, conducted Oct 2002 and Mar 2003.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000332059
Record of building HVAC and environmental inspections conducted for 280 Rector Place in November 2002.
9 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000116169
Report detailing HVAC and environmental inspections performed by Athenica Environmental Services in January 2003.
6 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132808
Inspection form for HVAC units at a NYC address dated November 6, 2002.
1 shared non-person entities · 1 shared topics · similarity 0.937
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
9 shared non-person entities · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132828
Inspection report listing fan models and conditions at a NYC address in November 2002.
1 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000132823
Inspection report listing fan models and conditions at a NYC address in November 2002.
1 shared non-person entities · 1 shared topics · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000114019
Report letter from Athenica Environmental Services regarding HVAC and environmental inspections at 333 Rector Place in late 2002.
8 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000115031
Inspection report for HVAC ducts at 261 Water Street checking for possible World Trade Center debris contamination.
1 shared non-person entities · 1 shared topics · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
11 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000333063
HVAC inspection details and qualifications for WTC-related building.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117441
Report from Athenica Environmental Services regarding HVAC and environmental inspections at 375 South End Avenue.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333059
Agency coordination on HVAC inspections conducted Oct 31, 2002 and Mar 4, 2003.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333057
memo documenting HVAC and environmental inspections for a building at 375 Avenue, NYC, conducted Oct 2002 and Mar 2003.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117561
Cover letter from Athenica Environmental Services regarding HVAC and environmental inspections at 395 South End Avenue.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000332059
Record of building HVAC and environmental inspections conducted for 280 Rector Place in November 2002.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000333063
HVAC inspection details and qualifications for WTC-related building.
Similar indexed content
NYC-WTC_000333059
Agency coordination on HVAC inspections conducted Oct 31, 2002 and Mar 4, 2003.
Similar indexed content
NYC-WTC_000333057
memo documenting HVAC and environmental inspections for a building at 375 Avenue, NYC, conducted Oct 2002 and Mar 2003.
Similar indexed content
NYC-WTC_000332059
Record of building HVAC and environmental inspections conducted for 280 Rector Place in November 2002.
Similar indexed content
Report detailing HVAC and environmental inspections performed by Athenica Environmental Services in January 2003.
Similar indexed content