NYC 9/11 Public Portal Document

375 South End Avenue, Manhattan, NY December 09,2002

Inspection Details;

As part of the survey, the following HVAC system types were inspected by Mechanical and Environmental professionals and bulk sample was collected from exhaust duct in the basement-mechanical phone room. All identification data and visual inspections are documented in the attached checklists.

A. Kitchen and batliroom exhaust - located on the roof and basement B. HVAC (7)Units-located on the lobby. C. Compactor room exhaust&intake,CVD24 exhaust, gym exhaust(no filter installed)-located on the basement. D. Heeding for the East side of the hallways - located on the roof. E. Heating for the West side hallways - located on the roof. F. AJC# 1 for the elevator room - located on the upper bulkhead. G. A/C #2 for the elevator room - located on the bulkhead.

Summary cl Findings:

During our visual inspection of the various HVAC systems black dust (less than 1/16"' of an inch) was observed in the following exhaust fans. Exhaust fan)/8,t/16 located on the roof. Exhaust fan #01 -CVD24-iocated on the basement. This was recorded in the Ventilation system evaluation forms. Bulk sample was collected and WTC related dust was NOT detected by EMSL Analytical, Inc

Scope of work: WTC related dust must be removed from the following:

Exhaust fans #8,16 located on the roof along with their associated components and their ducts Compactor room exhaust #01& intake,CVD24 exhaust, gym exhaust(no filter installed)- located on the basement along with their associated components and their ducts.

Should you require any further information, please feel free to contact me.

Sincerely,

life’ Vasilis Bellos Director of Operations

Attachments: 1) Ventilation System Evaluation forms 2) EMSL Lab results & Chain of Custodies

CITY_21MC100_011103006

NYC-WTC_000333062

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000333062Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →