NYC 9/11 Public Portal Document
Centers for Disease Control and Prevention
National Institute for Occupational Safety and Health
Interim Bulk and Air Sampling Report
Monday, September 24, 2001
Investigators from the National Institute for Occupational Safety and Health (NIOSH) collected
bulk and air samples in areas immediately adjacent to the debris pile and on personnel actively
involved in rescue efforts on or in the vicinity of the debris pile to characterize potential and
actual occupational exposures. Below are the interim sampling results for Monday, September
24, 2001.
Bulk Samples
Metals
• 1 bulk sample of paint was collected from the steel superstructure of the WTC
o Calcium, chromium, iron, and zinc were found in concentrations greater than 10
mg/G
Air Samples
Carbon Monoxide
• 5 real-time personal breathing zone samples were collected for carbon monoxide
o Most time-weighted average concentrations were below 24 ppm (a torch cutter
had a time-weighted average concentration of 45 ppm)
o A maximum peak of 1170 ppm was observed on a steelworker on the debris pile
Mercury
• 1 personal and 1 area air sample were collected for mercury
o Trace amounts of mercury were detected on the air samples
Metals
• 2 personal and 2 area air samples were collected for metals
o Nothing of concern was found regarding metal analysis
Polynuclear Aromatic Hydrocarbons (PAHs)
• 4 personal air samples were collected for PAHs
o Trace amounts of 15 different PAHs were identified
Respirable Dust
• 2 personal air samples were collected for respirable dust
o Personal sample 8-hour time-weighted average concentrations were below 0.09
mg/m^
yoladle Organic Compounds (VOCs)
• 3 personal air samples were collected with charcoal adsorbent tubes for VOCs
o No VOCs were detected on two of the air samples (trace amounts of benzene and
toluene were detected on 1 of the air samples)
K.M. Wallingford 10/15/01
CITY_21MC100_003066948
NYC-WTC_000332110
OCR can misread numbers and units. Confirm readings against the page image before using them.