McCall & Spero Environmental, Inc. Info page Page 1 of 1

Transmission Electron Microscopy (TEM) vs. Phase Contrast Microscopy (PCM)

1. PCM cannot visualize fibers less than 5.0 microns in length or 0.25 micron in width. In our experience, this makes up the majority of asbestos released during abatement activity.

2. PCM cannot distinguish asbestos from non-asbestos fibers.

3. TEM can visualize fibers less than 0.5 microns in length and 0.01 micron in width.

4. TEM can differentiate asbestos from non-asbestos fibers using morphology, selected area electron diffraction (SAED), and energy dispersive x-ray analysis (EDXA).

5. TEM is technically superior and more defensible in a court of law.

6. “EPA strongly recommends that abatement site air clearance collected from public & commercial buildings be analyzed by TEM at NVLAP accredited labs.” (EPA Federal Register Vol. 59, No. 23, Thursday, February 3,1994)

7. TEM is now widely available and a cost effective methodology for assuring the safest conditions possible for ambient & final air clearance monitoring.

The following micrographs are from the same final clearance air filter. The TEM micrographs are examples of structures not counted by PCM.

11^ '

PCM TEM i TEM Scope Mag. 40OX Scope Mag. 15,500X Scope Mag. 15,500X F/cc=0.0043 S/cc = 0.1120 S/cc = 0.1120 F/mm^=14.6 S/mm"=379.9 S/mni^=379.9

http://www.mselabs.com/msctemvspcm.html 10/9/01

CITY_21MC100_004089272

NYC-WTC_000332088

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000332088Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000279330

First draft outlining TEM/PCM methods for asbestos identification and analysis.

Similar indexed content

Compare copies and versions →