JLC ENVIRONMENTAL CONSULTANTS. INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212)420-8119 Fax: (212)420-6092 Project No,: 03-2744 New York City D.E.P. ELAP Lab Code; 11029 Analyte: FIBERS -17 Junction Blvd. NIOSH and AIHA Lab Code: 100273 Date Received: 3/6/2003 rlushing, NY 11373 NVLAP Lab Code; 101953 Date Analyzed: 3/6/2003

SUMMARY OF ANALYTICAL RESULTS - PCM Site: j 114 Liberty Street, New York, NY

SAMPLE # COLLECTED DESCRIPTION / LOCATION TIME(min) VOLUME(L) FIB/FIELD RESULTS(f/cc) LAB#

001 Adjacent to the 1st Front Entrance to Building 840 4258.8 5/100 <0.001<LOD 06-March #114 Liberty Street A 6779

002 At the Center/ In Front of Building #114 Liberty 840 4258.8 3/100 <0.001<LOD 06-March Street A 6780

003 Adjacent to the 2nd Entrance at the Front Building 840 4258.8 3/100 <0.001<LOD 06-March #114 Liberty Street A 6781

04 To the Far Right of the Back Entrance of Building 840 4258.8 11/100 0.001 j6-March #114 on Cedar Street A 6782

005 Adjacent to the Back Entrance of Building #114 on 840 4258.8 6/100 <0.001 06-March Cedar Street A 6783

006 FIELD BLANK 0/100 06-March A 6784

Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/100 Fields VOID1 = H.C.P. ( High Concentration of Particles) Positive Phase Contrast Microscopy (PCM) VOID2 = Overloaded Method of Sample Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2, August 1994 Instrumentation: MaCnhiwala” Olympus PCM Model BH-2 with Walton-Beckett Graticule (tOOum field diameter). Laboratory Director

Report Date: March 12, 2003 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this method gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs beyond the above. Page 3 of 8

CITY_DEP_WORBY_CANNATA_SUBP_000036141

NYC-WTC_000331757

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000331757Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →