OSHA SAMPLING RESULTS SUMMARY AS OF 11/16
Asbestos: A total of652 air monitoring samples for asbestos have been taken. From 9/13
-9/21, 177 samples were taken in the financial district. They were taken on
OSHA personnel as they walked within certain predetermined zones. Results
revealed asbestos concentrations ranging from ND (none detected) to .037
fZcc., well below OSHA’s permissible exposure limit (PEL) of .1 f/cc.
After 9/21, sampling focused on the rubble pile and those workers working on
or immediately next to it. 63 of the samples analyzed exceeded O SHA’s limit
via PCM analysis. However, upon further analysis using discriminating
counting methods and/or TEM analysis, the number of asbestos fibers found
dropped dramatically to below detectable levels or well below .1 f/cc.
Carbon Monoxide: A total of 47 personal samples of workers on the rubble pile showed results
ranging from 1 ppm to 34 ppm which are well below the OSHA 50 ppm
permissible exposure limit.
Noise: OSHA has been conducting noise monitoring in the rubble pile. Twelve
personal samples have been conducted on employees performing (or working
near) various operations such as jack hammering. Employee’s exposure to the
noise range from 80.6 dBA to 89 dBA. OSHA’s permissible noise exposure
for construction is 90 dBA
Respirable
SiUca: The overwhelming maj ority of the 240 silica samples show no detectable levels
of airborne silica. Howver, the highest sample result was approximately nine
times the OSHA limit on pre-drillers working on the bathtub wall. The next
highest level was twice the OSHA limit during rubble removal and loading
operations near the Winter Garden. Both of these levels were found on
personnel working in the rubble pile; an area where OSHA continues to
encourage the use of respiratory protection.
VolatUe Organic
Compounds: OSHA has taken 366 samples for (VOCs) such as acetaldehyde, acrolein,
acrylonitrile, benzene, 2-butanone, carbofurans, chlorodiphenyl (PCB), ethyl
benzene, formaldehyde. Freon R-22 (chlorodiflouromethane), hexone,
isocyanates (e.g. MDI, TDI), perchloroethylene, phosgene, styrene, toluene,
1-3 butadiene, trichloroethylene, vinyl chloride, and xylene. Screening
samples initially showed elevated levels of some organic chemicals resulting
from the fires burning in the rubble pile. Subsequent personal and area
samples show worker exposure levels to be below OSHA limits. However, one
personal sample result for benzene was found to be at the 8-hr. OSHA
Allowable Limit concentration of 1 ppm. This was found on a backhoe
operator moving debris. See information below for polynuclear aromatics,
Freon R-22, phosgene and dioxin.