NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM identification, H.S. for Economics & Finance, Oct 2001

Machine-extracted title · confidence 28%

TEM identification by SAED/EDS for project site in NYC, Oct 2001.

NYC-WTC_000330195
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No., 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: H.s. for Economies & Finance, 100 Trinity Pl., NYC TEM Sample No.: 5606 - 60120 Entire Buildincr Date.Received; 10/04/01 Grid Openings Analyzed;^_ 4

Project Sample No.: HSBF-S-10/3-42 Average,Grid Opening: 106.00 um

Air Volume: 1820 liters Total Area Analyzed: 0.044 9 nim2

Filter Type: MCE 25 mtn diam, , Fore Si~ze: 0.45 urn Analytical Sensitivity; 22.3 s/tmn2 Effective Area; 385 iTini2 0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct >*5um Struct/nMn2 Struct/cc n<7m/m3

Chrysotile Asbestos 1 0 0 '0 1 1 22.2 0.0047 155

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 1 1 22.2 0.0047 155 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 1 1 . 22.2 0.0047 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. this laboratory is in compliance with the quality specified for the method.

Analyzed by. Report Reviewed by.

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003274925

NYC-WTC_000330195

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000330195Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →