ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/05/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) with Fiber Identification by Selected-Area Electron Diffraction (SAEDl and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Aiialvsia Parameters

Project/Site; H.S. for Bcpnomics & Finance, IQQ Trinity Pl., NYC TEM Sample No. •.560£j:€0117 Entire Building Date Received: 1^/04/^ Grid Openings Analyzed;__4

Project Sample No.: HSEF-E-10/3-39 Average Grid Opening: 106.00 um

Air Volume: 1810 liters Total Area Analyzed: 0.O4S0 mm2

Filter Type; MCE 25 fnm diam. , Pore Size; 0.4S uro .Analytical Sensitivity; 22.2 s/min2 Effective Area: 385 mm2 0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. , Struct. Filter i Air ' Fibers Bundles Clusters Struct. Struct. >»5utn Strucc/mm2 Struct/cc nqm/ml

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures). 0 0 0.0 0,0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 , 0 0 0 0 0 0.0 0,0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Thnphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003274922

NYC-WTC_000330192

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000330192Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000340298

TEM analysis with SAED/EDS for AHERA method, project site at H.S., 10/04/01

Similar indexed content

Compare copies and versions →