ATC Associates 104 East 25 Street, New York, NY 10010 <4 Phone:(212) 353-8280 Fax:(212) 353-8306

Attn: Mr. Bernard Orlan Received: 12/26/2002 5:30:00 PM N.Y.C. Board of Education ATC Group#: 9213 I 28-11 Queens Plaza North Analysis Date: 12/26/2002

i Long Island City, Fax: (212) 475-4122 NY 11101 Phone: (212)477-8941 Project: H.S.Of Economics And Finance. Project# 14584-865 100 Trinity Place, New York, NY

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Colum Analyzed Asb Type(s) O.S/u-5 5fl fS/cc) fS/mm’) (S/cc) Notes

1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 9213 -I

7 1936.00 0.0450 0 NoneDetected 0 0 0.0044 <22.24 <0.0044 92^3 -2

3 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 9213 -3

4 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 9213 -4

5 1920.00 0.0450 0 NoneDetected 0 0 0.0045 <22.24 <0.0045 9213 -5

6 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 9213 -6

7 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 9213 -7

MARK PEYSAKHOV MICHAEL A GORYCKI, Ph.6.

Analyzed by: Approved by:

i Disclaimer The laboratory is not responsible fo' data reported in structures/cc, which s dependent on volume collected by non-laboratory personnel. This YA oniy responsible ( I for data reported in structures/mm^. This report may not be reproduced, except in full, without written approval Sy ATC Associates Inc. This repcn may rot be used to claim : product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (Including 95% confidence limits and laboratory and analysis accuracy and precision! is available upon request.

I Accredited for tiVLA.P PLM/TEM #101187-0, NY State ELAP #-10879

Thursday, December 26, 2002 Pii«e 1 ofl

CITY_21MC100_011276913

NYC-WTC_000329807

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000329807Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000405093

TEM asbestos analysis for H.S. project at Trinity Place; results and notes.

Similar indexed content

Compare copies and versions →