NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Wipe sampling report, PCBs, High School of Economics and Finance

Machine-extracted title · confidence 32%

Wipe samples collected to test for PCBs at the school location.

NYC-WTC_000329802–000329803
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St, 10th Floor New York, New York 10010 WWW. atc-en viro. com 212.353.8280 ASSOCIATES INC. Fax 212.353.8306

January 15, 2003

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101 -4008

Re: Wipe Samples for Polychlorinated Biphenyls High School of Economics and Finance (M833) 100 Trinity Place New York, New York ATC Project No. 15-19125-0291

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of the results of the wipe samples for polychlorinated biphenyls (PCBs) collected on December 30, 2002, at the referenced location. The New York City Department of Education (DOE) requested these samples to verify that acceptable indoor environmental conditions are being maintained.

Scope of Work

The samples were collected using sterile gauze pads and hexane as a solvent. The solvent was provided and samples were analyzed by PSC Analytical Services, Inc. (PSC), an American Industrial Hygiene Association-accredited laboratory in Reading, PA. The PCB analysis was performed using EPA Method 8082B.

Tenzin Namgyal, Industrial Hygienist of ATC’s New York City office, collected the samples consistent with generally accepted industrial hygiene practices. The results of the sampling represent conditions found on the date the samples were collected.

The sample area for each wipe sample was 100 square centimeters (lOOcm^). The areas sampled were: • Main lobby floor; • 5* Floor Hallway by stair B • 10* Floor by Stair B.

Results

ATC submitted three samples for PCBs to PSC for analysis. A copy of the laboratory' report is provided in the Attachment. Each sample was analyzed for seven (7) PCB compounds (see Atachment) containing different percentages of chlorine.

CITY_21MC100_003273781

NYC-WTC_000329802

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000329802Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000310601

Report of PCB wipe sample results collected at the school building in May 2002.

Similar indexed content

NYC-WTC_000404419

ATC report of PCB wipe sample results for the BOE at 100 Trinity Place, March 2002.

Similar indexed content

Compare copies and versions →