NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Indoor air quality report, PS 124M, Sep 2002

Machine-extracted title · confidence 52%

DOE indoor air quality measurements at PS 124M, September 2002.

NYC-WTC_000329460–000329463
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St., 10th Fl Nev/ York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 AS S 0 C I AT E S INC.

September 11, 2002 i j Mr. Bernard P. Orlan Director, Environmental Health & Safety I New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008

Re; Indoor Air Quality Assessment P.S.124M ii 40 Division Street New York, New York 10002 ATC Project No. 15-19125-0350

Dear Mr. Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of indoor air quality (lAQ) measurements collected on September, 10, 2002 at the referenced school. The New York City Department of Education (DOE) requested these measurements as part of a program to verify that acceptable indoor air quality is being maintained.

SCOPE OF WORK

ATC conducted this evaluation to assess the basic parameters of temperature, relative humidity, carbon dioxide (CO,) and carbon monoxide (CO).

Total volatile organic compounds (TVOCs) and respirable particulates were also measured.

.Mark Nakhumovich, Environmental Technician of ATC’s New York City office, conducted the assessment. ATC’s findings are based on a visual inspection, real-time environmental measurements and conditions present in the school at the time of the assessment.

ATC measured temperature, relative humidity, CO, and CO with a Q-Trak® Model 8551, manufactured by TSI, Inc.

ATC measured concentrations of respirable particulates (PM2.5) with a Dust-Trak® Aerosol Monitor Model 8520, manufactured by TSI, Inc. •

ATC measured concentrations of TVOCs using a RAE Systems, Inc. MiniRAE® photoionization detector (PID).

The assessment was performed consistent with generally accepted indoor air quality assessment practices. As with all such assessments, there were inherent limitations created by constraints of time, operational and work practice variability, variations in, indoor air quality parameters and sampling and analytical accuracy.

’ciTYZMMcrmFody^^

NYC-WTC_000329460

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000329460Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →