NYC 9/11 Public Portal Document
104 East 25th St., 10th Fl
New York, New York 10010
v/ww.atc-enviro.com
212.353.8280
■ Fax 212.353.83Q8
ASSOCIATES INC.
September 23, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, NY 11101
I
Re: Air Sampling for Metals
P.S. 124M
ATC Project No. 15-19125-0350
Dear Mr. Orlan;
ATC Associates Inc. (ATC) is pleased to provide this report of air sampling for metals in
airborne dust conducted on September 12, 2002, in the referenced school building. The
New York City Department of Education (DOE) requested this sampling to verify that f
acceptable indoor air quality is being maintained.
Scope of work
ATC collected three (3) samples for metals at specified locations. Samples were
collected for ten (10) hours using 37 mm mixed cellulose ester filters connected to
battery-powered sampling pumps at a flow rate of 2 liters per minute. Pumps were
calibrated before and after each sampling period. All samples were collected inside the
building. Two blanks were also submitted. The samples were sent to PSC Analytical
Services, Inc., an American Industrial Hygiene Association-accredited laboratory in
Reading, PA. Analysis was performed by NIOSH Methods 7300M. Each sample was
analyzed for a panel of twelve (12) metals. The metals were aluminum (Al), cadmium lI i
(Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (pb), magnesium (Mg),
manganese (Mn), molybdenum (Mo), nickel (Ni) and zinc (Zn). A copy of the analytical
laboratory report is attached.
Tenzin Namgyal, Industrial Hygienist, and Sonny Ramlal, Environmental Technician, of
ATC’s New York City office, collected the samples consistent with generally accepted
industrial hygiene practices. The results of the sampling represent conditions found on
the date the samples were collected.
The sampling locations were as follows: Floor Main Lobby, 2nd Floor Hallway by
Room 222, and 3rd Floor Hallway by Room 307.
cITY_2iMC10 cTbba 273214
NYC-WTC_000329411
OCR can misread numbers and units. Confirm readings against the page image before using them.