NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

PCDD/PCDF Analyses Report, ATG Associates

Machine-extracted title · confidence 52%

Analyses report detailing PCDD/PCDF results from samples submitted by ATC Associates.

NYC-WTC_000329171–000329172
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ’ace Analytical' REPORT OF: CHEWIIGAL AISIALYSES Minneapolis, Phone: 612.607.1700 www.pacelabs.coni Fax: 612.607.6444

PROJECT PCDD/PCDF ANALYSES DATE: October 17; 2002

ISSUED TO; ATG Associates REPORT N0:02-l 062185 Attn: Mr. Jim Cohn 25th Street, 10th Floor New York, NY 10010

INTRODUCTION

This report presents the results from the analyses performed on three samples that were submitted by a representative of ATC Associates. The samples were analyzed for the presence or absence of polychlorinated dibenzo-p-dioxins !PCDps) and dibenzofurans (PCDFs) using a modified version of USEPA Method 8290.

SAMPLE IDENTIFICATION

Client ID Sample Type Date Received Pace ID

ATC-0904-42M-DX1 Wipe 09/05/02 103829057 ATC-0904-42M-DX2 Wipe 09/05/02 103829065 ATC-0904-42M-DX3 ; Wipe 09/05/02 103829073

DISCUSSION

The recoveries of the isotopically-labeled PCDD/PCDF internal Standards in the sample extracts ranged from 73-165%. Several labeled internal standard recoveries obtained for this project were above the target range specified in Method 8290. However, since the quantifications of the native 2,3,7,8-substituted isomers were based on isotope dilution, the data were automatically corrected i for variation in recovery and accurate values were obtained.

A laboratory method blank was prepared and analyzed with each sample batch as part of our routine quality control procedures. The results, found at the beginning of Appendix B, show one bi«: of the blanks to contain a low level of non-2,3,7,8-substituted TCDD. All of the samples j7 i contained a similar level of this isomer and are flagged "B" on the data summary sheets. In general, levels less than ten times the background are not considered statistically different from the background.; .7 . t I IC'' i I.'/-

REPORT OF LABORATORY ANALTSIS (' . ■ This reportshall not be reproduced, except in full. ' 7; without the written consent of Pace Analytical Services, Inc. ,

CITY_2IMC10 oZo0 3 2 729 70

NYC-WTC_000329171

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000329171Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000238629

Pace Analytical Services report presenting results for polychlorinated dibenzo-p-dioxins and dibenzofurans in samples submitted by ATC Associates.

Similar indexed content

Compare copies and versions →