Pace Analytical Services, Inc.
1700 Elm Street, Suite 200
’ace Analytical' REPORT OF: CHEWIIGAL AISIALYSES
Minneapolis,
Phone: 612.607.1700
www.pacelabs.coni Fax: 612.607.6444
PROJECT PCDD/PCDF ANALYSES DATE: October 17; 2002
ISSUED TO; ATG Associates REPORT N0:02-l 062185
Attn: Mr. Jim Cohn
25th Street, 10th Floor
New York, NY 10010
INTRODUCTION
This report presents the results from the analyses performed on three samples that were submitted
by a representative of ATC Associates. The samples were analyzed for the presence or absence of
polychlorinated dibenzo-p-dioxins !PCDps) and dibenzofurans (PCDFs) using a modified version of
USEPA Method 8290.
SAMPLE IDENTIFICATION
Client ID Sample Type Date Received Pace ID
ATC-0904-42M-DX1 Wipe 09/05/02 103829057
ATC-0904-42M-DX2 Wipe 09/05/02 103829065
ATC-0904-42M-DX3 ; Wipe 09/05/02 103829073
DISCUSSION
The recoveries of the isotopically-labeled PCDD/PCDF internal Standards in the sample extracts
ranged from 73-165%. Several labeled internal standard recoveries obtained for this project were
above the target range specified in Method 8290. However, since the quantifications of the native
2,3,7,8-substituted isomers were based on isotope dilution, the data were automatically corrected
i for variation in recovery and accurate values were obtained.
A laboratory method blank was prepared and analyzed with each sample batch as part of our
routine quality control procedures. The results, found at the beginning of Appendix B, show one
bi«: of the blanks to contain a low level of non-2,3,7,8-substituted TCDD. All of the samples
j7 i
contained a similar level of this isomer and are flagged "B" on the data summary sheets. In
general, levels less than ten times the background are not considered statistically different from
the background.; .7 . t
I IC''
i
I.'/-