Scope of Work

ATC Associates, Inc. (ATC) was retained by New York City Department of Education (NYC-DOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples were collected from areas recommended by the NYC- DOE. These areas are the following:

• Outside the Building, Small Playground Surfaces - Three (3) samples • Outside the Building, by the Main Entrance - Three (3) samples • Outside the Building, Large Playground Surfaces - Five (5) samples • T* Floor Hallway - One (1) sample • Cafeteria - One (1) sample • Auditorium One (1) Sample • Gymnasium - One (1) sample • Throughout 2"*^ floor - Six (6) samples • Throughout 3”“ floor - Seven (7) samples • Throughout F‘ floor - Five (5) samples

The purpose of the dust wipe sampling is to determine if dust in the school contains lead. ATC’s representative Mr. Herant Antonyan visited P.S. 234M located at 292 Greenwich Street, New York, NY on December 23, 2002. Dust wipes to be analyzed for lead content were collected from the aforementioned areas indicated by the New York City Department of Education Environmental Health & Safety Unit and in accordance with HUD protocols.

LEAD-IN-DUST SAMPLING Lead-in-dust threshold levels The New York City Health Code, part 173.14 and the Federal Departments of Housing and Urban Development (HUD) and Environmental Protection Agency (EPA) have established acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred (commonly referred to as “final clearance” levels). As stated in the Code, final clearance after abatement has taken place is achieved when dust wipe samples indicate lead levels below those listed below:

For Window sills: 250 pg/ff For Floors: 40 pg/ft^ For Exterior Concrete or Rough Surfaces: 800 pg/tL

Although the lead-in-dust samples collected at P.S. 234M were not collected in response to lead abatement, the same thresholds are used since no other regulations or standards are applicable to this project.

Sampling Methodology ATC provided all laboratory analytical services in support of this limited inspection. ATC is certified by the New York State Department of Health’s Environmental Laboratory P.S. 234M (Swre AESOCIATEB INC. December 24, 2002

CITY_21MC100_011276735

NYC-WTC_000329136

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000329136Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →