104 East 26th St., 10th Fl New York, New York 10010

ASSOCIATES •.-'C INC. www.atc-enviro.com 212,353.8280 Fcx 212 353.8306

August 30, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Department of Education 28-11 Queens Plaza North; Long Island City, NY 11101

Re: Air Sampling for Hydrocarbons P.S. 150M ATC Project No. 15-19125-0289

Dear Mr. Orlan;

ATC Associates, Ind. (ATC) is pleased to provide this report of the results of air sampling for hydrocarbon compounds conducted on August 20, 2002, at the referenced school. The New York City Department of Education (NYCDOE) requested this sampling to verify that acceptable ' indoor air quality is being maintained.

Scope of Work

ATC collected three (3) samples for hydrocarbon compounds (HG) at, specified locations. Satnples were collected for a minimum of ten (10) hours usingi activated coconut shell charcoal tubes connected to battery-powered sampling pumps/at a flow rate of 0.2 liters per minute. ) Pumps were calibrated before and after each sampling period. Two (2) samples were collected from outside the building and one (1) was collected inside. One blank tube was also submitted. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene ' Association-accredited laboratory in Reading, PA. Analysis was performed by ,capillary gas chromatography/flame ionization defection (OSHA Method 7).

Tenzin Narngyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York City office, collected the samples consistent with accepted industrial hygiene sampling practices. The results represent the conditions on the day the samples were collected.-

Each sample was analyzed for a panel of sixteen (16) specific HC compounds. These compounds were: pentane, acetone, methylene chloride, hexane, chlorofonn, methyl chloroform, benzene, 1,2-dichloroethane, trichloroethylene, toluene, perchloroetyhylene (tetrachloroethylene), chlorobenzene, eihylbenzene, styrene, cumene and xylenes. In addition, two nbn-identified peaks, total other A- hydrocarbons and total other B-hydrocarbons, were reported. The A- hydrocarbons are those, such as gasoline or light alcohols, with boiling points less than that of benzene (176°F). The B-hydrocarbons are those, such as mineral spirits or petroleum naphtha, with boiling points greater than that of benzene ., A copy of the analytical report is attached..

The sampling locations were the Plaza (Outdoors), the Main Lobby and the Roof.

CITY_21MC100_003272514

NYC-WTC_000328786

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000328786Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →