NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
Phone: (212) 353-8280 Fax;(212)353-8306
Attn: Mr. Bernard Orlan Received: 8/24,'02 3:00:00 AM
N.Y.C. Board of Education ATC Group#: 8745
28-1! Queens Plaza North Analysis Date: 8/24/02
Long Island City, NY 11101
Fax; (212) 475-4122 Phone: (212)477-8941
Project; NYC-BOE PS 2M Project #: 14584-870
122 Henry Street, New York, NY.
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CER Part 763 Final Rule (AHERA)
Analytical Asbestos
Area !\’on Asbestos # Structures Sensitivity Concentration
Sample Coltiine Analyzet! Asb Type(s) 9.S/1-5 5/t (S/cc) (S/mm^) (S/cc) Notes
1 1936.00 0.0450 0 ■Mane Detected 0 0 0,0044 <22,24 <0.0044
8745 -!
1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0,0044
574.1
3 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
8745 -J
4 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
8'745 -4
5 1936.00 0.0450 0 Nona Detected 0 0 0.0044 <22.24 <0.0044
8745 -5
6 1952.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
S745 -6
1952,00 0,0450 0 None Detected 0 0 0.0044 <22,24 <0.0044
S745 -7
MARK PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
Analyzed by: (proved by:
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This laDis only responsible
for data reported in structures/mml This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other acency of the U.S. Government. This reports relates only to the samples reported above. Guality control data (including S5%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accrecited for NVLAP PLM/TEM #101187-0, N* State ELAP #10879
Page I n/3
-t.
CITY_21MC100_011276551
NYC-WTC_000328632