Scope of Work
ATC Associates, Inc. (ATC) was retained by New York City Department of Education
(NYC-DOE) to collect dust wipes to be analyzed for lead content. Dust wipe samples
were collected from areas recommended by the NYC- DOE. These areas are the
following:
• 5™ Floor Hallway
• 4* Floor Hallway
• 3'^ Floor Hallway
• 2"'^ Floor Hallway
• r‘Floor Hallway
• Basement Hallway
• V' Floor Lobby
• Cafeteria
• Auditorium
• Two random Classrooms
The purpose of the dust wipe sampling is to determine if dust in the school contains lead.
ATC’s representative Mr, Mark Nakhumovich visited Murray Bergtraum H.S. (M520)
located at 411 Pearl Street, New York, NY on September 9, 2002. Dust wipes to be
analyzed for lead content were collected from the aforementioned areas indicated by the
New York City Department of Education Environmental Health & Safety Unit and in
accordance with HUD protocols.
LEAD-IN-DUST SAMPLING
Lead-in-dust threshold levels
The New York City Health Code, part 173.14 and the Federal Departments of Housing and
Urban Development (HUD) and Environmental Protection Agency (EPA) have established
acceptable lead-in-dust levels for re-occupancy after a lead abatement has occurred
(commonly referred to as “final clearance” levels). As stated in the Code, final clearance
after abatement has taken place is achieved when dust wipe samples indicate lead levels
below those listed below:
For Window sills: 250 pg/ft^
For Floors: 40 Llg'it'
Although the lead-in-dust samples collected at Munay Bergtraum H.S. were not collected
in response to lead abatement, the same thresholds are used since no other regulations or
standards are applicable to this project.
Sampling Methodology
ATC provided all laboratory analytical services in support of this limited inspection. ATC
is certified by the New York State Department of Health’s Environmental Laboratory
Murray Bergtraum H.S. (M520)
(Swrc
A5BOCIA1ES INC.
September 10, 2002
CITY_2 IMCl Li U_U U 1 8 2 7 8 5 9
NYC-WTC_000328618
OCR can misread numbers and units. Confirm readings against the page image before using them.