NYC 9/11 Public Portal Document
BlO-921-9BG7 P-4
Sep 19 02 a3;4ep PSC
INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING
F’SC
• EPANVL4P101262-0 • NY DOH/NEIAC10903 •NJ DEP PAO20
«AIHA ACCREDITATION NO. 100433 • PA OEP 06-353 ■ CT DPH PH-0238
■NCDENR 599
Analytical Results
for
ATC Associates
WorkOrder: R0209039]
Client Reference: M52O
Analyte Concentration Limit nf Test Date Analyzed
Detection Method /Analyst
(ug) (msDiT) : (ppm) (ug)
Client ID: ATC-09! 1-M520-S1 Lab ID: -01A Date Sampled:9/11/02 Matrix: AirVol.(L): 1020
Respirable Particulate Matter <50.0 <0.0490 50 N0600 09/17/2002 ADM
Silica (Quartz Total) <5.00 <0.00490 5 AIRBORNE SILICA 09/17/2002 ADM
Client ID: ATC-0911-M520-S2 Lab ID: -02A Date Sampled; 9/11/02 Matrix: AirVol.{L): 1020
Respirable Particulate Matter <50.0 <0.0490 50 N0600 09/17/2002 ADM
Silica (Quartz Total) <5.00 <0.00490 5 AIRBORNE SILICA 09/17/2002 ADM
Client ID: ATC-09] 1-M520-S3 Lab ID: -03A Date Sampled: 9/11/02 Matrix; AirVol.(L): 1020
Respirable Particulate Matter <50.0 <0.0490 50 N060Q 09/17/2002 ADM
Silica (Quartz Total) <5.00 <0.00490 5 AIRBORNE SILICA 09/17/2002 ADM
Client ID: ATC-0911-M520-S4 LablD;-04.A Date Sampled; 9/11/02 Matrix: Air VoI.(L); NA
Respirable Particulate Matter <50.0 50 N06Q0 09/17/2002 ADM
Silica (Quartz Total) <5.00 5 AIRBORNE SILICA 09/17/2002 ADM
(a) Analysis indicates possible breakthrough; back section result is greater than % of the front section result.
General Notes:
<: Less than the indicated limit of detection (LOD).
Information not available or not applicable.
Sack sections were checked and showed no significant breakthrough.
Page 1 of 1
CITY_21MC100_003272414
NYC-WTC_000328603
OCR can misread numbers and units. Confirm readings against the page image before using them.