104 East 25th St., 10th Fl New York, New York 10010 vi/ww.atc- envi ro.com 212.363.8280 Fax 212.353.8306 ASSOCIATES INC

September 19, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Mercury Vapor Murray Bergtraum High School (M520) ATC Project No. 15-19125-0351

Dear Mr. Orlan;

ATC Associates, Inc. (ATC) is pleased to provide this report of the results of air sampling for mercury (Hg) vapor conducted on September 11, 2002, at the referenced school. The New York City Department of Education (DOE) requested this sampling to verify that acceptable indoor air quality is being maintained.

Scope of Work

ATC collected thi'ee (3) samples for Hg vapor using Carulite® (Hydrar) tubes connected to battery-powered sampling pumps calibrated to collect 0.2 liters of air per minute. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association- accredited laboratory in Reading, PA. One blank tube was also submitted. Analysis was performed by means of a mercury vapor analyzer according to NIOSH Method 6009. A copy of the analytical laboratory report is attached.

Tenzin Namgyal, Industrial Hygienist and Sonny Ramlal, Environmental Technician from ATC’s New York City office, conducted the sampling consistent with accepted industrial hygiene practices. The results represent the conditions on the day the samples were collected.

The sampling locations were; P' floor Main Lobby, 3"* floor Hallway by Room 339 and 5* floor Hallway by Room 518.

Results

Mercury (Hg) was detected in these samples at levels that were indistinguishable from that detected in the blank.

The established regulatory value for mercury (O.lmg/m’) is intended for industrial workplace exposures and is not generally applicable to office/school settings. There are no standards for mercury in indoor air in non-mdustrial situations. The EPA has no standard or guideline for mercury vapor in ambient air.

CITY_21MC100_003272366

NYC-WTC_000328578

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000328578Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →