(Swrc AS S O C I A T E S 1 N C . ' 104 East 25th St., 10th Fl New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306

September 19, 2002

Mr. Bernard P. Qrlan Director, Environmental Health and Safety New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Metals High School for Leadership & Public Service (M894) ATC Project No. 15-19125-0290

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this report of the results of air sampling for metals conducted on September 5, 2002, at the referenced school. The New York City Department of Education (DOE) requested these samples to verify that acceptable indoor air quality'is being maintained. i Scope of Work

ATG collected four (4) samples for metals in air. Samples were collected for ten (10) hours. Three (3) samples were collected inside the building and one (1) was collected outdoors. Two blank filters were also submitted. The samples and blanks were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in Readiiig, PA. A copy of the analytical laboratory report is attached.

The samples were collected using 37 mm mixed cellulose ester filters connected to battery- powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and after each sampling period. Analysis was performed by NIOSH Methods 7300M. Each sample was analyzed for a panel of eleven (12) metals. The metals were aluminum (Al), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), lead (pb), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni) and zinc (Zn).

Tenzin Namgyal, Industrial Hygienist from ATC’s New York City office, conducted the sampling consistent with accepted industrial hygiene practices. The results represent conditions on the day the samples were collected.

The locations of the samples were; 1 floor Main Lobby, 5* floor Hallway near the elevator, the 10“’floor Hallway near the elevator, and the Roof by the air intake.

Results

Chromium was detected in all of the samples obtained (including the blanks). Cr was the only metal detected. Blank-correcting (average blank concentration = 0.376 micrograms) the results lowers the Cr concentrations to below the limits of detection for the analyses.

CITY_21MC100_003272228

NYC-WTC_000328429

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000328429Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000239983

Letter from ATC Associates reporting air sampling for metals conducted at the school in February 2002.

Similar indexed content

Compare copies and versions →