Indoor air quality measurements collected on May 2, 2002 for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC provides indoor air quality findings for PS 89M per BOE request.
NYC-WTC_000328365–000328368OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 16, 2002 Indoor Air Quality Assessment Page 3 P. S. 89M ATC Project No. 15-19125-0297
Real-Time Environmental Measurements
ATC collected eighty (80) sets of real-time environmental measurements consisting of seventy- one (71) from inside the school building and nine (9) from outdoors. All five floors of the school building were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded at approximately 11:30 A.M.
Temperature
Indoor dry bulb temperature measurements ranged from 61.4°F to 75.6 °F. Sixty-nine (69) of the indoor measurements for temperature were below and two (2) were within the range of 73 to 79°F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the summer season . The outdoor temperature measurements ranged from 55°F to 56.1 °F.
Relative Humidity
The relative humidity indoors ranged from 27 to 37.2 percent. Thirty-three (33) of the indoor measurements for relative humidity were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 28.3 to 29.8 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 437 ppm to 1053 ppm. All of the indoor measurement for CO2 were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 436 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1136 ppm (background level + 700 ppm). Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of COp indoors is occupant respiration. The school building was occupied during ATC’s assessment.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 1 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline Of 9 ppm. The outdoor CO concentrations were 1 ppm for all collected readings. .
Respirable Particulates (PM2,5)
Respirable particulate concentrations* indoors ranged between 5 pg/m^ to 18 pg/m^. -phe average PM2.5 concentration for the entire school building was approximately 11 pg/m3. All of the indoor measurements were below the NPAAQS of 65 pg/m3 24-houT average concentration of particulate matter 2.5 micrometers or les.s in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m3 for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged from 17 to 25 pg/m^ with an average of 22 pg/m3. , •
CITY_21MC1OO_OO3272O34
NYC-WTC_000328367
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000328323
Indoor air quality measurements collected on May 2, 2002 for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313667
ATC measurements for PS 89M on May 15, 2002, temperature and humidity.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328214
Indoor air quality measurements report for P.S.89M, April 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328314
Indoor air quality measurements collected on April 26, 2002 for the school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394514
IAQ measurements collected April 30, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392864
ATC report of IAQ measurements at PS 89M requested by BOE.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369711
ATC IAQ measurement report for PS 89M school, May 2002, for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394477
IAQ measurements collected April 25, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313589
Indoor air quality measurements collected at PS 89M for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369833
ATC report of IAQ measurements at P.S. 89M requested by BOE, dated May 21, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392756
ATC report detailing indoor air quality measurements at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369801
ATC IAQ measurements at PS 89M for BOE; May 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000313667
ATC measurements for PS 89M on May 15, 2002, temperature and humidity.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392864
ATC report of IAQ measurements at PS 89M requested by BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370073
ATC IAQ measurement report for PS 89M at date of June 18, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369789
ATC IAQ measurements at PS 89M for BOE; May 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370061
ATC reports indoor air quality measurements taken June 17, 2002 at PS 89M for BOE evaluation.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370089
ATC IAQ measurements conducted June 20, 2002 at PS 89M for BOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000328323
Indoor air quality measurements collected on May 2, 2002 for PS 89M.
Similar indexed content
NYC-WTC_000313667
ATC measurements for PS 89M on May 15, 2002, temperature and humidity.
Similar indexed content
NYC-WTC_000328214
Indoor air quality measurements report for P.S.89M, April 2002.
Similar indexed content
NYC-WTC_000328314
Indoor air quality measurements collected on April 26, 2002 for the school.
Similar indexed content
NYC-WTC_000394514
IAQ measurements collected April 30, 2002 at the referenced school.
Similar indexed content