NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

ATC memo, Mar 1, 2002

Machine-extracted title · confidence 55%

ATC memo reporting IAQ measurements at PS 89M (Mar 1, 2002).

NYC-WTC_000327495–000327498
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Oflan ■ 2 March 1, 2002 Moor Air Quality Assessment Page 3 P. S. 89M 2 ATC Project No. 15-19125-0297

Real-Time ENVfRONMENTAL Measurements

ATC collected eighty (80) sets of real-time environmental measurements consisting of seventy- one (71) from inside the school building and nine (9) from outdoors. AU five floors of the school building were surveyed. These results are described below.

Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded at approximately 11:50 A.M.

Temperature

Indoor dry bulb temperature measurements ranged from 65,3°F to 72.3°F. Three (3) of the measurements were below the range of 68 to 75°F (at 50 percent relative humidity) as recommended by the, ASHRAF Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature measurements ranged from 33.3 to 35.1°F.

Relative Humidity

The relative humidity indoors ranged from 11.8 to 26.8 percent. All of the measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 31.0 to 33.0 percent.

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 534 ppm to 1100 ppm. All of the COp measurements were within the ASHRAE Standard 62-1999 recommended maximum concenfration of <700 ppm above the background level. The maximum outdoor (background) COp concentration was 441 ppm. Therefore^ the maximum acceptable level of GOp at this location was 1141 ppm (background level + 700 ppm). The highest GO2 measurement was collected from room 402. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of COp indoors is occupant respiration. The school building was occupied during ATG’s assessment.

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors were 0 ppm for all readings.. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentration was also 0 ppm for all collected readings.

Respirable Particulates (PM2_3d

Respirable particulate concentrations* indoors ranged between 7 jug/m^ to 222)ug/m3, None of the measurements were above the NFAAQS of 65 jug/m3 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The average PMp,5 concentration for the entire school building was approximately 11 pgZm^. The PMp.5 average concentration was below the USEPA recommended concentration-'of 40 jag/m? for sensitive

CITY_21MC100_003271026

NYC-WTC_000327497

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000327497Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →