NYC 9/11 Public Portal Document

Mr. Bernard P. Grlan February 8,2002 Indoor Air Quality Assessment P. S. 89M ATC Project No. I5-T9I25-0297

The assessment was perfomied consistent with generally accepted indoor air quality assessment practices. As with all such assessments, there were inherent limitations created by constraints of time, operational and work practice variability, variations in indoor air quality' parameters and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presenteci in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities. A

EVALUATION CRITERIA

Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:

Vsntilation for Acceptable Indoor Air Quality (ASIIRAH 62-1999), Amencw Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditionsfor Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.

i'A ■ TABLEI TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED TARGETi LlATi _________ ' niza: ______ Carbon Dioxide <700 parts per million (ppm) ASI iRAi; 62 (GO2) V above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NPAAQS) 65 micrograms per cubic meter USEPA NPAAQS Respirable of air (pg/m^i 24-hour average Particulates (PM2.5) 40 |ug/iii^ 24-hour average USEPA - recommendation for children/sensitive individuals Temperature Summer; 73-79°F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30 - 60 % ASHRAE55 Total Volatile Organic Compounds 1 Rpm AlIIA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AWA = American Industrial Hygiene Association

CITy_21MC10 0_0 03 2-7 0 821

NYC-WTC_000327375

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000327375Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →