Air silica sampling report, P.S. 89M, Aug 2002

Machine-extracted title · confidence 41%

ATC letter report of silica-containing dust air sampling at P.S. 89M, Aug 16, 2002.

NYC-WTC_000327034–000327035
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

<Satc ASSOCIATES INC. 104 East 25th St., lOth Fl New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306

August 28, 2002

Mr. Bernard P. Orlan ' Director, Environmental Health and Safety New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Silica P.S.89M ATC Project No. 15-19125-0297

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for silica- containing dust conducted on August 16, 2002 at the referenced school. The New York City. Department of Education (DOE) requested this sampling .prior to the resumption of classes to verify that accepta.ble indoor air quality is being maintained.

Scope of Work

ATC collected ten (10) samples respirable dust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. All samples were collected indoors. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. One blank filter was also submitted. Silica analysis was performed by x-ray diffraction according to OSHA Method 142. A copy of the analytical laboratory report is attached.

Wagdi Abdelshahid, Industrial Hygienist of ATC’s New York City office, collected the samples consistent with generally accepted industrial hygiene practices. The results of the sampling represent conditions found on the date the samples were collected.

The sampling locations were: the floor hallway (North), T‘ floor hallway (South), Cafeteria, Gymnasium, Auditorium, Room 202,(South), Room 204 (East), Room 226 (North), 2"^ floor hallway (South), and 4'*’floor hallway (South)./

Results

Silica was not present above the limit of detection (<5 micrograms per sample) in any of the ten samples.

CITY_21MC1OO_OO327O387

NYC-WTC_000327034

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000327034Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000393491

Laboratory-report style letter detailing silica air sampling at PS 89M.

Similar indexed content

Compare copies and versions →