(Sktc 104 East 25th St., 10th Floor New York, New York 10010 wvwv.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

May 6, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New' York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101 -4008

Re: Wipe Samples for Dioxins P. S. 89M ATC Project No. 15-19125-0297

Dear Mr. Orlan:

ATC Associates Inc . (ATC) is pleased to provide this report of the results of the wipe samples for polychlorinated dibenzo-p-dioxins (PCDDs)and dibenzofurans (PCDFs) collected on March 15, 21 and 28, 2002 at the referenced location. The New York City Board of Education (BOE) requested these samples to evaluate possible contamination in the school building per the recommendation of Environ Corp., consultant to the parents association..

SCOPE OF WORK

The samples were collected using gauze pads and hexane as a solvent. The pads and solvent were provided and samples were analyzed by Pace Analytical Services, Inc. (Pace) of Minneapolis, MN, a laboratory experienced in dioxin analysis. The analysis was performed by modified EPA Method 8290 using combined-capillary column gas chromatography/high ■ resolution mass spectrometry.

Wagdi Abdelshahid, Industrial Hygienist of ATC’s New' York City office, collected the samples consistent with generally accepted industrial hygiene practices. There w'ere inherent limitations created by constraints of time, operational, and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates the samples were collected.

WIPE SAMPLING RESET.TS

On each day, ATC submitted three (3) wipe samples for PCDDs/PCDFs to Pace for analysis. A copy of the laboratory analysis report is provided in the Attachment. Samples were taken from areas specified by the parents association consultant. The area of each sample one (1) square meter (Im^).

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor.

CITY_21MC100_012156702

NYC-WTC_000326675

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000326675Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →