Method 8290 Analysis Results
Client-aTC
Client's Sample ID ATC-0222-89M-DX4
Lab Sample ID 103343448
Filename U20312A_12
injected By CVS
Total Amount Extracted 1 1712 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/22/2002
ICAL Date 03/12/2002 Received 02/25/2002
CCai Filename(s) U20312A_06 & U20312A_21 Extracted 03/05/2002
Method Blank ID BLANK-1499 Analyzed 03/12/2002 19:18
Native Cone EMPC LRL Internal ng’s Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND —- 0.0021 A 2,3,7,8-TCDF-13C 2.00 S5
Total TCDF nd ----- 0.0020 2,3,7,8-TCDD-13C 2.00 61
T,2,3,7,S-PeCDF-13C 2.00 65
2.3.7,8-TCDD ND 0.0036 A 2,3,4,7,3-PeCDF-13C 2.00 66
Total TCDD ND 0,0020 1,2,3,7,3-P©CDD-13C 2.00 S8
1,2,3.4.7,8-HxCDF-13C 2.00 95
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6.7,8-HxCDF-13C 2.00 74
2.3,4,7,8-P0CDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 78
Total PeCDF ND 0.0100 1,2,3,7.8,9-HxCDF-13C 2.00 71
1,2.3,4,7,8-HxGDD-13C 2.00 110
1.2.3,7,6-PeCDD ND 0.0100 1.2,3,6,7,8-HxCDD-13C 2.00 76
Total PeCDD ND 0.0100 1,2,3,4,6,7,S-HpCDF-13C 2.00 96
1,2,3,4,7,a.9-HpCDF-13C 2.00 38
1,2,3,4,7.8-HxCDF ND 0.0100 1,2,3,4,6,7,a-HpCDD-13C 2.00 102
1,2,3,6,7.8-HxCDF ND 0.01 DO OCDD-13C 4.00 76
2,3,4.6,7,8-HxCDF ND 0.0100
1,2,3,7,8.9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2,00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 61
1,2,3,6,7,8-HxCDD ND 0.0100
1.2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0,0100
1,2,3,4.6,7,a-HpCDF ND 0-0100 Total 2,3,7,8-TCDD
1.2,3,4.7,8,9-HpCDF ND 0,0100 Equivalence: 0.000049 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2.3,4,6.7.8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OGDD 0.049 0.0200 BJ
LHL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,B-SUbstltuttd isomers) I = Intarferenca
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-naise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis *■= See Discussion
Report No.... 02-1054416
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_005390277
NYC-WTC_000326654
OCR can misread numbers and units. Confirm readings against the page image before using them.