NYC 9/11 Public Portal Document
Pace Analytical Services, inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
TM
■ /
^ace Analytical ______ Tel: 612-607-1700
Fax: 612- 607-6444
/ Method 8290 Analysis Results
/
Client - ATC
Client's Sample ID ATC-1220-89M-DX4
Lab Sample ID 103233920
Filename F11228B_06
i Injected By
Total Amount Extracted
% Moisture
BAL
1 m2
NA
Matrix
Dilution
WIPE
NA
i Dry Weight Extracted
ICAL Date
NA
11/19/2001
Collected
Received
12/20/2001
12/21/2001
CCa Filename(s) F11228B_01 & F11228B_16 Extracted 12/23/2001 ■
Method Blank ID BLANK-1389 Analyzed 12/29/2001 01:30
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TGDF 0.0026 0.00200 J 2,3,7,8-TCDF-13C 2.00 58
Total TCDF 0.0540 0.00200 2.3,7,8-TCDD-13C 2.00 72
1,2.3,7,8-PeCDF-1.3C 2.00 59
2,3,7,'8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 59
Total TCDD 0.0840 0.00200 1,2,3,7,8-PeCDD-13C 2.00 71
1 1,2,3,4,7.8-HxCDF-13C 2.00 73
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxDDF-13C 2.00 73
2,3,4,7,8-PeCDF ND 0.01000 2.3.4.6,7.8-HxCDF-13C 2.00 74
Total PeCDF 0.0220 0.01000 J 1,2,3.7,8.9-HxCDF-13C 2.00 71
1,2,3,4,7,8-HxCDD-13C 2.00 98
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 78
Total PeCDD 0.1000 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 72
1,2,3.4,7.8.9-HpCDF-13C 2.00 67
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3.4,6,7.8-HpCDD-13C 2.00 81
1.2,3,6,7,8-HxCDF ND 0.01000 OGDD-13C 4.00 56
2,3,'4,6,7.8-HxCDF ND 0.01000
1,2,3.7,8,9-HxCDF ND 0.01000 1,2.3.4-TCDD-13C 2.00 NA
Total HxCDF 0.0200 0.01000 J 1,2,3,7,B,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 75
fl 1,2,3,S.7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
is. Total HxCDD 0.1600 0.01000
1,2,3.4.6,7,8-HpCDF 0.0210 0.01000 J Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ' ND 0.01000 Equivalence; 0.0013 ng/m2
Total HpCDF 0.0210 . 0.01000 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0480 0.01000 J
IJI Total HpCDD 0.0890 0.01000 J
OCDF 0.0230 0.02000 J-
OCDD 0.3100 0.02000
3
ta LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EM PC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applioabis
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 01-1052540
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC1OO_O12156685
NYC-WTC_000326609
OCR can misread numbers and units. Confirm readings against the page image before using them.