Mr. Bernard P. Orlan Januai-y 29, 2002 Indoor Air Quality Assessment Page 3 ATC Project No. 15-19125-0297

Real-Time Environmental Measurements

ATC collected ninety-two (92) sets of real-time environmental measurements consisting of fift/- two (52) inside the school building and ten (10) outdoors in the morning (A.M.) followed by twenty-two (22) inside and eight (8) outside in the afternoon (P.M.). All five floors of the school were surveyed. These results are described below.

Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded after 3:30 P.M. 7

Temperature

Indoor dry bulb temperature measurements ranged from 65.8 “F to 73.3 °F (A.M.) and 69.5°F to 73.6°F (P.M ). Only four measurements were below the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). These were A.M. readings on the Pf floor. The outdoor temperature measurements averaged 52°F (A.M.) and 62.8°F (P.M.).

Relative Humidity

The relative humidity indoors ranged from 24.9 to 35.1 percent (A-M.) and 25.8 to 31.5 percent (P.M.) . Only seven A.M. and four P.M. readings measurements were within the ASHRAE- recommended range of 30 to 60 percent for occupant comfort. The remainder were below the recommended range. The outdoor relative humidity averaged 37:7 percent (A.M.) and 30.5 percent (P.M.). 'v ■

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 549 to 1159 ppm (A.M.) and 481 to 630 ppm (P.M.). Two (2) CO2 measurement was above the ASHRAE Standard 62-1999 recominended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentrations averaged 553 ppm (A.M.) and 483 ppm (P.M ). Therefore, the maximum acceptable level of GO2 at this location was 1253 ppm (backgroimd level + 700 ppm). The highest CO2 reading was found in Room 408. At the time of ATG’s assessment, this room was occupied by approximately twenty-eight (28) people. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of COg indoors is occupant respiration. The school building during ATC’s assessment was not occupied.

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors were 0-1 ppm for all readings. These concentrations were below the ASHRAE guideline of 9 ppm. The outdoor CO concentration was also 0-1 ppm.

CITY_21MC100_003270160

NYC-WTC_000326047

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000326047Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

IAQ memo, PS 89M, Jan 2002

NYC-WTC_000400632

Report of indoor air quality measurements at PS 89M; January 28, 2002.

Similar indexed content

Compare copies and versions →