NYC-WTC_000325981
Indoor air quality report for PS 89M, January 2002.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗IAQ measurements collected at PS 89M, January 2002.
NYC-WTC_000326016–000326019OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
(Srtc 104 East 25th Street 10th FL Mew York. New York 10010 : www.atc-enviro.com 212.353.8280 Tax 212;363A306 S S O C I A T E S I N C .
January 24, 2002
Mr. Bernard P. Orlan Director, Environmental Healtlr & Safety New. York City Board of Education 2 8 -11 Queen s Plaza North Long Island City, NY 11101-4008
Re: Indoor Air Quality Assessment -T — P.S.89M .)■ 201 Warren Street New York, New York 10282 ATC Project No. 15-19125-0297
Dear Mr. Orlan:
ATC Associates Inc. (ATC) is pleased to provide this report of indoor air quality (lAQ) measurements collected on January 23, 2002, at the referenced school. The New York City Board of Education (BOE) requested these measurements as part of a program to determine if acceptable indoor air quality is being maintained. .
SCOPE OF WORK
ATC conducted this evaluation to assess the basic parameters of temperature, relative humidity, carbon dioxide (COj) tod carbon monoxide (GO).
Total volatile organic compounds (TVOCs) and respirable particulates (PM2.5) were also measured. '-; ■ ■ i;.- ;
Mr. Timmy Choy, Industrial Hygienist of ATC’s New York City office, conducted the assessment. ATC’s findings and Conclusions are based on a visual inspection, real-time en vironmental measurements and conditions present in the school at the time of the assessment.
ATG measured temperature, relative humidity, COj and CO with a Q-Trak® Model 8551, manufectured by TSI, Inc.
ATG measured concentrations of respirable particulates (PM2.5) with a Dust-Trak® Aerosol Monitor Model 8520, manufactured by TSI, Inc.
ATC measured concentrations of TVOGs using a RAE Systems, Inc. MiniRAE® photoionization detector (PID).
CITY_21MC100_003270119
NYC-WTC_000326016
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000325981
Indoor air quality report for PS 89M, January 2002.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326012
IAQ report for S-PS 89M, January 2002.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000327378
Indoor air quality measurements collected February 8-11, 2002 for PS 89M.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000327414
Indoor air quality measurements collected February 13, 2002 at a referenced school.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326767
ATC IAQ measurements at PS 89M, March 7, 2002, for NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359707
Indoor air quality measurements at PS 89M, 201 Warren Street, Jan 2002.
11 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400594
Report of indoor air quality measurements at PS 89M for BOE project.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326825
ATC IAQ measurements at PS 89M, March 14, 2002, per BOE.
12 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000384033
ATC report of IAQ measurements collected January 23, 2002 at PS 89M for NYC BOE.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000327350
ATC IAQ report for the NYC Board of Education; measurements to assess air quality before occupancy.
12 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226873
ATC Associates report on indoor air quality measurements collected at P.S. 89M on January 17, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000327362
ATC memo noting IAQ measurements at a NYC school requested before re-occupancy.
13 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000326002
IAQ measurements at PS 89M, January 2002, ATC Associates.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000325981
Indoor air quality report for PS 89M, January 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000325993
IAQ measurements collected at the referenced school in Jan 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373529
Indoor air quality report for P.S. 234M, January 22, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400563
IAQ report for January 18, 2002, at PS 89M with multiple measurements.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400572
IAQ report for January 21, 2002 at P.S. 89M with measurement results.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000325981
Indoor air quality report for PS 89M, January 2002.
Similar indexed content
NYC-WTC_000326012
IAQ report for S-PS 89M, January 2002.
Similar indexed content
NYC-WTC_000327378
Indoor air quality measurements collected February 8-11, 2002 for PS 89M.
Similar indexed content
NYC-WTC_000327414
Indoor air quality measurements collected February 13, 2002 at a referenced school.
Similar indexed content
NYC-WTC_000326767
ATC IAQ measurements at PS 89M, March 7, 2002, for NYC BOE.
Similar indexed content