NYC-WTC_000382855
TEM asbestos analysis for PS 89M air samples; includes analytical details.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, N ew York, NY 10010 Phone: (212) 353-8280 Fax:(212) 353-8306
. Attn: Ml'. Bernard Orlan Received: 3/27/02 7:00:00 PM N.Y.C. Board of Education ATC Group #: 7230 28-11 Queens Plaza North ' Analysis Date: 3/27/02 Long Island City, NY 11101
Fax: (212) 475-4122 Phone; (212)477-8941
Project: PS S9M 201 Warren Street, New York;, NY Playground, Roof All Floors Hallway
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rulc (AtlETLA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Type(s) O.S/i-S 5fi (S/cc) (S/mm^) (S/cc) Notes
01 1840.00 0.0450 0 None Detected 0 P 0.0047 <22.24 <0.0047 7230 -i
02 - ( 1840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <(1.0047 7230 -2 7
03 •i 840.00^ 0,0450 0 . None Detected 0 . 0 0.0047 <22.24 <0.0047 7230 -3
04 840.00 0.0450 0 None Detected ,0 0 0.0047 <22.24 <0.0047 7230 -4
OS: , I 840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047 7230-5
06 1840.00 0.0450 0, None Detected 0 0 0.0047 <22.24 : <0.0047 7230 -6
■07 1840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047 7230 -7
MICHAEL A. GORYCKI, Ph.D. ROMAN PEYSAKHOV Analyzed by ^proved by:
Disclaimer: The laboratory is not responsible for data reported in structures/cc, wiiicti is dependent on volume collected by non-laboratpry personnel. This lab is only responsible for data reported in structures/mmL Tfiis report may not be reproduced, except in full, without written approval by ATC Associates Inc, This report may not be used to claim product endorsement by, NVLAP or any other agency of the U.S. Government, This reports relates only-tothe samples reported above. Quality cohtro! data (including 95% , confidence limits and laboratory and analysis'accuracy and precision) is avaiiable upon request.
Accrediied for NVLAP FOMCEM #101187-0, NV State ELAP #10879
1 Page lof? '
CITY_21MC100_011275886
NYC-WTC_000325781
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000382855
TEM asbestos analysis for PS 89M air samples; includes analytical details.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000325828
Asbestos TEM analysis performed for PS 89M playground project at 201 Warren Street, Mar 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000393298
Air monitoring data chain-of-custody documentation, May 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274380
Asbestos TEM analysis results for PS 89M playground project at Warren Street, Mar 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313033
Asbestos fiber TEM analysis for PS 89M project, playground area at 201 Warren Street, using AHERA method.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382780
TEM asbestos analysis for PS 89M playground samples, submitted Mar 13, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394151
Asbestos TEM analysis for PS 89M air samples, May 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382687
TEM asbestos analysis results for PS 89M samples 6911.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244868
TEM asbestos analysis data for PS 89M project; results and notes.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370240
Asbestos TEM analysis results for PS 89M playground samples, 06/24/02.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313164
TEM asbestos results; PS 89M playground samples, June 10 entry.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000201473
Summary sheet of asbestos fiber analysis results for P.S. 89M samples received on April 17, 2002, performed under EPA AHERA guidelines.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000201438
Report from ATC Associates detailing transmission electron microscopy results for asbestos fiber analysis on an air sample from a school playground.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000393371
Air monitoring chain-of-custody for TEM analyses, May 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313033
Asbestos fiber TEM analysis for PS 89M project, playground area at 201 Warren Street, using AHERA method.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000393298
Air monitoring data chain-of-custody documentation, May 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382855
TEM asbestos analysis for PS 89M air samples; includes analytical details.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382836
AHERA TEM asbestos analysis results for PS 89M Playground area, Mar 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000382855
TEM asbestos analysis for PS 89M air samples; includes analytical details.
Similar indexed content
NYC-WTC_000325828
Asbestos TEM analysis performed for PS 89M playground project at 201 Warren Street, Mar 2002.
Similar indexed content
NYC-WTC_000393298
Air monitoring data chain-of-custody documentation, May 2002.
Similar indexed content
NYC-WTC_000274380
Asbestos TEM analysis results for PS 89M playground project at Warren Street, Mar 2002.
Similar indexed content
NYC-WTC_000313033
Asbestos fiber TEM analysis for PS 89M project, playground area at 201 Warren Street, using AHERA method.
Similar indexed content