28-11 Queens Plaza North ATC Group#: 6550
Long Island City, NY 11101 Analysis Date: 2/3/02
Fax; (212) 475-4122 Phone: (212) 477-8941
Pro ject: PS 89V 201 Warren Street, New York, NY
Playground, Roof ,1st Floor Hallway
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos Structures Sensitivity Concentration
I'olume Analyzed Asb Type(s) O.Sy-5 5y (S/cc) , (S/cc) Notes
Sample
01 1840,00 0.0450 0 Nona Detected 0 0 0.0047 <22.24 <0.0047
6550 -1
02 1840,00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
6550 -2
03 1848,00 0.0450 0 None Detected 0 0 0.0046 <22.24 <0.0046
6550 -3
04 1840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
6550 -4
05 1840.00 0.0450 0 None Deteoted 0 0 0.0047 <22.24 <0.0047
6550 -5
05 1840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
6550 -6
07 1840.00 0.0450 0 None Detected 0 .0 0.0047 <22.24 <0.0047
6550 -7
08 1840.00 0,0450 0 None Detected 0 0 0.0047 <22.24 . <0.0047
6550 -8
MICHAEL A. GORYCKI, Ph.D.
ROIMAN PEYSAKHOV
Analyzed by: Approved by:
Disclaimer: The laboratory is not responsible tor data reported in structures/cc, wiiicti is dependent on volume collected by non-laboratory personnel. This lab is only responsible
for data reported in structuresfrrim’ This report may not be reproduced, except in full, without written approval by ATC Associates Inc, This report may not be used to claim
product endo'sement by NVLAP or any other agency of the U.S, Government. This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited fo- NVLAP PLMHEM #101187-6, NY State ELAP #1087S