NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
'J
Phone: (212) 353-8280 Fax; (212) 353-8306
Attn: Mr. Bernard Orlan Received: 4/30/02 8:00:00 PM
N.Y.C. Board of Education ATC Group#: 7587
28-11 Queens Plaza North Analysis Date: 4/30/02
Long Island City, ./NY 11101
Fax: (212)475-4122 Phone: (212)477-8941
Project: PS 89M 201 Warren Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos a Structures Sensitivity Concentration
Sample t'niume Analyzed Asb Type(s) 0.5/1-5 5/1 (S/cc) fS/mm^) fS/cc) Notes
01 1840.00 0.0450 . 0 None Detected 0 0 0.0047 <22.24 <0.0047
7587 -I
02 1840-00 / 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
■7587 -7
03 1840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
.7587 -3-
04 1840.00 0.0450 0 None Detected 0 0 -• 0.0047 <22.24 <0.0047
. 7587 .4
05 1840.00 0.0450 , .0 None Detected 0 0 0.0047 <22.24 <0.0047
7587 -5
06 1848.00 / 0.0450 0- None Detected 0 0 0.0046 <22.24 . <0.0046
7587 -6
07 1840.00 ' 0.0450 0 None Delected 0 G 0.0047 <22.24 <0.0047
r 7587-7-
MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: Approved by:
s
Disclaimer: The laboratory is not responsible for data reported in,structures/cc, which is dependent-on volume collected by non-laboratory personnel. This labTSonly responsible_ i
for data reported in structures/mm7 This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis'accuracy and precision) is available upon request. . ■ -
Accredited for NVLAP PLWTEM #101187-0, NY State ELAP #10879
Page 1 of 2
NYC-WTC_000324983
OCR can misread numbers and units. Confirm readings against the page image before using them.