NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 20 pages

TEM analysis, PS 234M, Oct 2001

Machine-extracted title · confidence 41%

TEM analysis with SAED/EDS for PS 234M, Oct 2001.

NYC-WTC_000324339–000324358
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y-C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1137 Long Island City, NY 11101 Report Date: 10/02/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by selected-Area Electron Diffraction (SAEDI and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Pinal Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identifrcaticn Analysis Parameters

Project/Site: P.S. 234M, 2S2 Sreenwich St., RY, RY TEM Sample No.: 5592 59906 Entire School Date Received: 10/02/01 Grid Openings Analyzed;__ 4

Project Sample No.: P5234M-ES~10/2-12 Average Grid Opening; 106.00 urn

Air Volume; _iJ,2Ciiters Total Area Analyzed:0^,045D mn2

:er Type: MCB 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity:2Z^.2^/rnTn2 Effective Area: 385 mm2 Q.0047 s/cc

FIBROUS ~ARTICULATES ANATYZBD Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ncm/mS

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.oooc 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes airhiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0 . 0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_OO32681O5 NYC-WTC_000324350

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324350Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →