NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM analysis, H.S. for Economics & Finance

Machine-extracted title · confidence 28%

TEM asbestos analysis with SAED/EDS for Economics & Finance site, Oct 2001.

NYC-WTC_000324299
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document (

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State EL.AP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/05/Cl

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEMi With Fiber Identification by Selected-Area Electron Diffraction !SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rula, EPA Federal Register (40 CFR, Part 763), Vol- 52, No. 210, October 30, 1987

Sample Identification Analysis' Paramecars

Project/''Site: H.S. for Economics £ Finance, 100 Trinity Pl., NYC TEM Sample No.: 5606 SOILS Entire Building Date Received: 10/04/01 Grid Openings Analyzed:__ 4

ProjecC Sample No. HSBF-S-10/3-39 Average Grid Opening: 1Q6.0Q um

Air Volume: 1310 liters Total Area Analyzed: Q.045Q mrn2

Filter Tyte.- MCS 25 mm diam. Pere Size: 0.45 urn Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385 nim2 0,0047 s/c

FIBROUS PARTICULATES ANALYZED Mumber Observed CONCENTRATION Tocal Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >=:»5um Struct/mm2 Struct/cc nom/mS

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.cooo 0

Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Idencification 0 0 0 0 0 0 0.0 0 . 0000 N/A

Totals (Ail Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type.- None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_2IMCI00_003267882 NYC-WTC_000324299

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324299Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000340297

TEM analysis with SAED and EDS identification for a high school project, 10/05/01

Similar indexed content

Compare copies and versions →