ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/05/01 ., ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEMi With Fiber Identification by Selected-Area Electron Diffraction (SASD) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method; AHERA Final Rula, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 3'0, 1987

Sample IderXification Analysis Parameters

Project/Site; H.S. for Economics &. Finance. 100 Trinity Pl NYC TEM Sample No.; 5606 60093 Entire Building Date Received; 10/04/01 Grid Openings Analyzed:__ 4

Project Sample No. : Average Grid Opening: 106.QO urn

Air Volume: 1310 libers Total Area Analysed ;p^.04S 0 jnm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 urn Analycical Sensitivity: 22.2 s/mm2 Effective Area: 385 mm! 0 . 0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundlas Clustsrs Struct. Struct >-5um Struct/rnm2 Struct/cc ncm/m3

Chrysotile Asbestos 0 0 0 0 0 0 Q .0 0.QOOO 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 C 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0,0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0. 0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Str’dctures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type; None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003267859 NYC-WTC_000324277

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324277Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000340298

TEM analysis with SAED/EDS for AHERA method, project site at H.S., 10/04/01

Similar indexed content

Compare copies and versions →