AMBIENT AIR AND DUST SAMPLING PROTOCOL for PS234M. Page 2Qf8

All ambient air samples collected shall be analyzed via Transmission Electron Microscopy (TEM) in accordance with the methodology of the AHERA Final Rule.

Results from samples collected each day shall be reported verbally, no later than Sam the next day, to BOE, UFT, School Principal and the PA consultant. A written report shall be delivered or faxed by the end of the day. Unsatisfactory results (>70 s/mm^) shall be reported immediately.

In the event that any one sample result exceed 70 s/mm^ ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the UFT and the PA consultant. BOE shall notify the school principal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.

INDOOR AIR QUALITY

To address lAQ concerns, each day from Monday through Friday, the following shall be performed;

• A visual inspection to assess conditions present in the school at the time of the site visit.

• Collect approximately 60 real-time environmental measurements of temperature (T)

Collect approximately 60 real-time environmental measurements of relative humidity (RH)

• Collect approximately 60 real-time environmental measurements of carbon dioxide (CO2)

• Collect approximately 60 real-time environmental measurements of carbon monoxide (CO) • Collect approximately 60 real-time environmental measurements of total volatile organic compounds (TVOCs)

Coflect approximately 60 real-time environmental measurerrents of respirable particulates (PM2.5).

EVALUATION CRITERIA:

Since, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools at this time, for the real-time data collected, the commonly accepted guidelines cited in the following publications and table below shall be utilized:

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE): Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industnal Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AlHA).

.I CITY_21MC100_003267253

NYC-WTC_000324204

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324204Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →