AMBIENT AIR AND DUST SAMPLING PROTOCOL
FOR
H.S. of Economics and Finance (M 833)
I CD fDOOC
The New York City Board of Education (BOE) in an effort to address concerns regarding
Indoor Air Quality (lAQ) and potential asbestos contamination of the ambient air at the High
School of Economics and Finance following the World Trade Center (WTC) tragedy and
associated clean up work had established the following lAQ and ambient air
monitoring/assessment protocol:
ASBESTOS
To address the concerns regarding the potential of asbestos contamination of the ambient
air, daily air testing and analysis shall be performed, including Saturdays and Sundays, inside
and outside the school building as follows;
Inside the school building
The total of 11 ambient air samples shall be collected from inside the school building each
day as follows:
• First floor lobby outside the Auditorium - 2 samples (one sample from 3am-12pm & one
from 12pm-4pm)
• Cafeteria - one sample during the school day
• Auditorium - one sample during the school day
• Classrooms on the 4“’ Floor (randomly selected) - one sample immediately after the last
class
• Classrooms on the e* Floor (randomly selected) - one sample immediately after the last
•class
• Classrooms on the 8*^ Floor (randomly selected) - one sample immediately after the last
class
• Third floor Hallway - one sample immediately after the last class.
• Fifth floor Hallway - one sample immediately after the last class
• Seventh floor Hallway - one sample immediately after the last class
• Ninth floor Hallway - one sample immediately after the last class
Outside the school building
The total of 6 ambient air samples shall be collected from outside the school building each
day as follows:
CITY_21MC100_003267177
NYC-WTC_000324135