NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Asbestos fiber TEM analysis performed at the project/site throughout the school building, Oct 2001.
NYC-WTC_000324076OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State FLAP #10879 2S-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01
ASBESTOS FIBER ARIALYSIS SY TRANSMISSION ELECTRON MICROSCORY (TEM'l With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
sample laentificaticn Analysis Parameters
Proj ect/Sice: 130M. 143 Baxter St., NY, NY TEM Sanrole No.: 5726 61671 Throughout the School Building Date Received: -uUB/u:- Grid Openings Analyzed;_ 4
Project Sample Kc.; 15 Average Grid Opening; 106.00 urn
A.ir Volume: 1899 liters Total Area Analyzed: 0.04 50 111112
Filter T^^pe: Ml- 25 mm diam. , Pore Size: 0.45 um Analytical Sensitivity ;.^^2;2 s2mn^ Effective Area; 385 mm2 C.004E s/cc
FIBROUS PARTICULATES ANALYZED Number Observed COKCSKTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct /Tnni2 Struct/cc ngm/m3
Chrysotile Asbestos 0 0 0 0 0 0 C.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 c.o 0.0000 0
Total asbestos -(includes ambiguous structures) 0 u c.o 0.0000 0 Non-Asbestos 0 0 0 0 0 0 f: . 0 0.0000 N/A No 'Identification 0 0 0 0 c 0 C.0 0.0000 N/A
Totals (All Structures 1 c 0 C.O 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiberi.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed,by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. GcrycKi, Ph.D. Director of Electron Microscopy
CITY_21MC100_011274420
NYC-WTC_000324076
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
7 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329872
TEM asbestos analysis; SAED/EDS; 10/18/01.
5 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329861
Asbestos TEM analysis, AHERA method, PS 130M school building.
7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329856
TEM asbestos analysis results for PS 130M site, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411583
TEM asbestos analysis for PS 234M, 292 Greenwich St, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329871
TEM asbestos analysis; SAED/EDS; PS 110M project/site; 10/18/01.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262780
TEM asbestos analysis for PS 234M; SAED/EDS identification, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329854
AHERA TEM-based asbestos analysis for PS 130M site.
7 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329872
TEM asbestos analysis; SAED/EDS; 10/18/01.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329861
Asbestos TEM analysis, AHERA method, PS 130M school building.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329856
TEM asbestos analysis results for PS 130M site, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411583
TEM asbestos analysis for PS 234M, 292 Greenwich St, Oct 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
Similar indexed content
NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
Similar indexed content
NYC-WTC_000329872
TEM asbestos analysis; SAED/EDS; 10/18/01.
Similar indexed content
NYC-WTC_000329861
Asbestos TEM analysis, AHERA method, PS 130M school building.
Similar indexed content
NYC-WTC_000329856
TEM asbestos analysis results for PS 130M site, 2001.