ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date; 10/19/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TBM) With Fiber Ident ion by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Pinal Rule, E?A Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1967

Sample IdentitLcatior. Analysis Parameters

Project/Site-. P.S. 13QM. 14 3 Baxter S^ NY, NY TEM Sample No.-. 572S 61662 Throughout the School Buildinc Date Received: 10 <6/Cl Grid Openings Analyzed:__ 4

Project Sample No. Average Grid Opening:106;00 urri

Air Volume: 1506J^ Total Area Analysed; 0.0450 mm2

FiIt er Type: MCE 25 mm diam.. Pore Si 0.45 UTTi Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385 mmiz 0.0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air 'ibers Buncl Clusters Struct. Struct > = 5vm Struct/mmO Strvct/cc ncrm/TnS

Chrysotile Asbestos C C 0 0 0 0 0.c 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambicuous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.c 0.0000 0 Non-Asbestos 0 C 0 0 0 0 O.G 0.0000 K/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 C.0 0.0000 N/'A The estimated uncertainty oi this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SA.ED) -. None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance■with the approved TEM method. This laboratory is in compliance with the quality specified'for the method.

Analyzed by: Report Reviewed by:

Michael A, Gcrycki, Ph.D. Michael A. Gox Ph. D. Director of Electron Microscopy

CITY_21MC1OO_O11274402

NYC-WTC_000324063

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324063Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →