ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.y.C. Board of Education Approved N.Y. Soate ELA.P #10879 28-11 Queens Plaza North ACCREDITED NVLA? Lab Code # 1137 Long Island City, NY 11101 Report Daze: 10/10/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM; With Fiber Identification by Selected-Area Electron Diffraction (SAEDi and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AH2RA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identificar.ion Analysis Parameters

Project/Site: Murrv Bergtraum H.S., 411 Pearl .St. WY.. MY TEM Sample NO.: 5650 - 6C713 Basement & Flcors 1-5 Date Received: 10/09/01 Grid Openings Analyzed;_ 4

Project Sample Nc.; MEHS-B>6-I0/9-2i Average Grid Opening; 10g.30 um

Air Volume: L836 liters Total Area Analyzed 0^0.450 jTm2

F.llter T^/pe: MCE 25 rrm diafn., Pore Site: 0.45 um -Analytical Sensitivity: 22.2 s/mm2 Effective Area: 385 mm2 0.0047 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Tocal Single Matrix Total. Struct. Filter Air Fibers Bundles ■rs Struct.- Struct > = 5urn Struct/nrr.2 Struct/cc ncm/'mO

Ciirysotile Asbestos 0 0 0 0 0 Q Q .0 C.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0 . 0 C.030C Q

Ambiguous 0 0 0 0 0 0 0.0 0,0000 0

Total asbe.stos 'induces ambiguous structures! 0 0 0. c 0.0000 0

Non-Asbestos 0 0 0 0 0 0. 0 0,0000 N/A No Identi .un 0 0 0 Q 0 0 C. 0 0,0000 N/'A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (SDS/SAED): None detected Amphibole Asbescos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A, Gorycki, Fh.D. Director of Electron Microscopy

CITy_21MC100_003266958

NYC-WTC_000323965

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000323965Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →