NYC-WTC_000330199
TEM asbestos analysis with SAED/EDS for NYC DOE project, Oct 2001.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗Asbestos fiber analysis by TEM for a NYC Department of Education project site, Oct 2001.
NYC-WTC_000323957OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25ch Streec New York, New York 10CIO
N.Y.C. Board of Educaoion Approved N.Y. State ELAF #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: IC/lO/Ol
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TSM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: Murry Eergtraum H.3., 411 Pearl St NY, NY TEM Sample Nc.: 5650 - 50699 Ba.sement & Fleers 1-5 Date deceived: 10/09/01 Grid Openings Analysed:_ 4
Project Sample No..- M3HS-B>6-1UO-07 Average Grid Opening: 106.00 urn
A..r Volume; 1835 Total .Area Analyzed:C 0£5^mrn2
Filter Type: MCE 2g mrr ciam. . Pore 3 1.45 um Analytical Sensitivityt 22,2 sZmm2 Effective Area- SSommC 0,0 04'7 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Scrucc. Filter Air Fibers Pundies Cluste: Struct. Struct >=Sijrn Struct Struct/cc ncrm/ n3
Clirysotiie .Asbestos 0 0 0 0 0 ' 0 0 . 0 0.0000 0
A-nphibole Asbestos 0 0 0 0 0 0 0 .0 0.0000 0
Anbiguous 0 G 0 C 0 0 0 . 0 0.oooo 0
Total asbestos (includes ambiguous structures) c 0 0 . 0 0.0000 . 0
Non-Asbestos 0 0 0 c 0 c 0.0 0.0000 N/A
INO icentification 0 0 0 c c 0.0 0.0000 N/.A
Totals (All structures! c 0 0. n 0.0000 N/A The estimated uncertainty of thus analysis is 1 standard deviation..
Non-asbestos fiber i.d. (EBS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried ouc in accordance with the approved TEM method. This laboratory is in comipliance with the quality specified for the method.
Analyzed by: Report Reviewed by;
Marek Psvsakhcv Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003266947
NYC-WTC_000323957
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000330199
TEM asbestos analysis with SAED/EDS for NYC DOE project, Oct 2001.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270110
Asbestos fiber analysis by TEM (AHERA method) for Stuyvesant HS, floors 1-10, Oct 2001.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205255
Laboratory analysis report for asbestos fibers in air samples collected at the High School for Economics and Finance.
3 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248483
TEM analysis of asbestos at Stuyvesant High School, Oct 2001.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200249
Laboratory report from ATC Environmental showing asbestos fiber analysis by TEM for air samples collected at the High School for Economics and Finance.
2 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411521
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270218
TEM analysis parameters and results for NSHS sample NSHS-llMS-9/21-10.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000200248
Laboratory report from ATC Environmental showing asbestos fiber analysis by TEM for air samples collected at the High School for Economics and Finance.
2 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330194
TEM identification of asbestos fibers using SAED/EDS for NYC project, Oct 2001.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411474
TEM analysis results for asbestos at Floors 1–4, 328 W. 14th St.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330191
TEM asbestos analysis at HS for Economics & Finance, Oct 2001.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248500
TEM asbestos analysis by Selected-Diffraction for Stuyvesant High School.
4 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000329991
TEM results summary for Eduction Dept project at H.S. basement and floors 1-6, Oct 10, 2001.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329991
TEM results summary for Eduction Dept project at H.S. basement and floors 1-6, Oct 10, 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329991
TEM results summary for Eduction Dept project at H.S. basement and floors 1-6, Oct 10, 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330199
TEM asbestos analysis with SAED/EDS for NYC DOE project, Oct 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329991
TEM results summary for Eduction Dept project at H.S. basement and floors 1-6, Oct 10, 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270110
Asbestos fiber analysis by TEM (AHERA method) for Stuyvesant HS, floors 1-10, Oct 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000330199
TEM asbestos analysis with SAED/EDS for NYC DOE project, Oct 2001.
Similar indexed content
NYC-WTC_000270110
Asbestos fiber analysis by TEM (AHERA method) for Stuyvesant HS, floors 1-10, Oct 2001.
Similar indexed content
NYC-WTC_000205255
Laboratory analysis report for asbestos fibers in air samples collected at the High School for Economics and Finance.
Similar indexed content
NYC-WTC_000248483
TEM analysis of asbestos at Stuyvesant High School, Oct 2001.
Similar indexed content
NYC-WTC_000200249
Laboratory report from ATC Environmental showing asbestos fiber analysis by TEM for air samples collected at the High School for Economics and Finance.
Similar indexed content