Mr. Bernard P. Orian September 20, 2001 Respirable Dust Assessment Page 2 Murray Bersrtraum HS fM5201 ATC Project No. 15-19125-0247

The results of the sampling represent condition found on the date of the survey and may not represent conditions found at other times. The information presented in this report should be used by the Board of Education as a guide to assess the need for further- improvements in current indoor air quality control activities.

EVALUATION CRITERIA

Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publication:

Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE).

Table 1 lists target guideline for the parameter that ATC evaluated during this investigation. Meeting the listed value does not assure that acceptable indoor air quality will be achieved at all times.

TABLE 1 TARGET GUIDELINE FOR INDOOR AIR QUALITY PARAAIETER EVALUATED PARA.METER fi TARGET LEVEL AGENCY OR ORGANIZATION Respirable Particles 50 micrograms per cubic USEPA NPAAQS as cited in (PM,Q meter of air (ug,W) ASHRAf 62-1999 USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

RESULTS

ATC collected one hundred seven (107) measurements of respirable particulates randomly throughout the school. All but three (3) readings were below the ASHR.AE 62- 1999 guideline of 50 pg/m’ (See Attachment 1). Indoor concentrations ranged from 0 to 250 ug/mf The outdoor concentration was 0 ug/m^ due to hea\7 rain at the time of the assessment. Due to the sensitivity of the instrument used, levels recorded as 0 ug/m^ represent levels of less than 10ug/m\ This difference does not affect ATC’s conclusions.

OBSERVATIONS

The tliree areas with high dust readings were on the 6"' floor where .ATC observed dust on the furniture in the elevator lobby and on the gymnasium floor. Four large floor fans were running in the gymnasium at the time of ATC’s assessment. Other areas within the school were clean.

CITY_21MC100_011274324

NYC-WTC_000323949

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000323949Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →