ATC Associates is pleased to provide this report of an indoor air quality assessment.
8 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Respirable particulate assessment conducted at the referenced school.
NYC-WTC_000323948–000323951OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orian September 20, 2001 Respirable Dust Assessment Page 2 Murray Bersrtraum HS fM5201 ATC Project No. 15-19125-0247
The results of the sampling represent condition found on the date of the survey and may not represent conditions found at other times. The information presented in this report should be used by the Board of Education as a guide to assess the need for further- improvements in current indoor air quality control activities.
EVALUATION CRITERIA
Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publication:
Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE).
Table 1 lists target guideline for the parameter that ATC evaluated during this investigation. Meeting the listed value does not assure that acceptable indoor air quality will be achieved at all times.
TABLE 1 TARGET GUIDELINE FOR INDOOR AIR QUALITY PARAAIETER EVALUATED PARA.METER fi TARGET LEVEL AGENCY OR ORGANIZATION Respirable Particles 50 micrograms per cubic USEPA NPAAQS as cited in (PM,Q meter of air (ug,W) ASHRAf 62-1999 USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard
RESULTS
ATC collected one hundred seven (107) measurements of respirable particulates randomly throughout the school. All but three (3) readings were below the ASHR.AE 62- 1999 guideline of 50 pg/m’ (See Attachment 1). Indoor concentrations ranged from 0 to 250 ug/mf The outdoor concentration was 0 ug/m^ due to hea\7 rain at the time of the assessment. Due to the sensitivity of the instrument used, levels recorded as 0 ug/m^ represent levels of less than 10ug/m\ This difference does not affect ATC’s conclusions.
OBSERVATIONS
The tliree areas with high dust readings were on the 6"' floor where .ATC observed dust on the furniture in the elevator lobby and on the gymnasium floor. Four large floor fans were running in the gymnasium at the time of ATC’s assessment. Other areas within the school were clean.
CITY_21MC100_011274324
NYC-WTC_000323949
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000323931
ATC Associates is pleased to provide this report of an indoor air quality assessment.
8 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000323935
ATC Associates report of IAQ assessment at the referenced school in NYC.
7 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000381458
Report of respirable particulate sampling conducted in a NYC Board of Education school building.
5 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000323939
ATC Associates IAQ assessment report for the school in New York City.
8 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294488
ATC report of respirable particulate sampling at PS 234M across multiple dates in 2002.
5 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177878
Letter and report detailing respirable particulate sampling conducted to assess indoor air quality.
5 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353195
ATC reports real-time monitoring of respirable particulates at multiple BOE locations, March 7, 2002.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000249543
January 17, 2002 memo detailing respirable particulates air monitoring at PS 234M.
6 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353090
ATC report of respirable particulates monitoring at multiple NYC BOE locations, Feb 2002.
6 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373501
Real-time respirable particulates report for P.S. 234M, January 2002.
6 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000249546
January 18, 2002 memo detailing respirable particulates air monitoring at PS 234M.
6 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396213
ATC real-time air monitoring report for P.S. 234M, January 2002.
6 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000401062
April 1, 2002 letter presenting respirable particulate monitoring at a NYC school site.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308767
ATC report on six-date respirable particulate monitoring at the school building.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401078
ATC respirable particulate IAQ assessment report for Stuyvesant High School (M477), Apr 2002.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312462
Memo from ATC to NYC BOE about a respirable particulate IAQ study at a high school.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308751
February–March 2002 IAQ monitoring at the named high school to assess respirable particulates.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312114
ATC memo accompanying IAQ measurements for Stuyvesant High School conducted mid-November 2001.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000323931
ATC Associates is pleased to provide this report of an indoor air quality assessment.
Similar indexed content
NYC-WTC_000323935
ATC Associates report of IAQ assessment at the referenced school in NYC.
Similar indexed content
NYC-WTC_000381458
Report of respirable particulate sampling conducted in a NYC Board of Education school building.
Similar indexed content
NYC-WTC_000323939
ATC Associates IAQ assessment report for the school in New York City.
Similar indexed content
NYC-WTC_000294488
ATC report of respirable particulate sampling at PS 234M across multiple dates in 2002.
Similar indexed content