NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
ffi
REPORT DATE: 08-12-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
345 Chambers Street, NY
PROJECT NUMBER: M477-15217-29881
SAMPLED BY: Client
SAMPLE DATE: 08-09-02
DATE RECEIVED: 08-09-02
Lj DATE ANALYZED: 08-09-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(hg/ft^)
LW-01 21042 6th Floor Dance Studio Floor Adj.Left Window <9.0 9.0
LW-02 21042 6th Floor Dance Studio Table Top R.H.S. <9.0 9.0
FB-1 21042 Field Blank <9.0 pg 9.0 pg
FB-2 21042 Field Blank <9.0 pg 9.0 pg
NOTE 1:
U THE REPORTING LIMIT (RL) IS 18.0 pg
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 pg/fP, Window sills 250 pg/fF,
Window wells 400 pg/fF, Exterior surfaces 800 pg/ft’.
NOTE 3:
Blank units are in pg
CERTIFICATION AND SIGNATURES
ANALYSIS PERFORMED BY:
REPORT PREPARED BY:
ATC certifies that this report is an accurate and authentic report of results obtained from the laboratory analysis.
y
QUALITY ASSURANCE COORDINATOR:
LABORATORY DIRECTOR:
1
ATC is accredited by the New York State Department of Health Environmental Laboratory Approval Program (ELAP) and by the American
Industrial Hygiene Association (AIHA) to perform analysis of lead in paint, dust wipes, air and soil samples. (ELAP #10879), (AIHA #100229).
CITY_21MC100_003266417
NYC-WTC_000323371
OCR can misread numbers and units. Confirm readings against the page image before using them.